MAR2000
Set for Fresh water Operation
IMPORTANT OPERATING REQUIREMENTS:
WATER LEVEL IN DRUM RESERVOIR
115-120 mm (4.5 to 4.75 inches)
•
DRUM ROTATING SPEED
2.4 RPM (thick ice)
•
REFRIGERANT:
R-404A
•
REQUIRED CONDENSING CAPACITY
6500 Kcal/h at –24
•
o
BTUH at –11
F.)
WATER PRESSURE CONTROL SETTING
0.8 Bar (11 PSIG)
•
MAX. WATER TEMPERATURE
o
35 °C (95
F)
•
MIN. WATER TEMPERATURE
o
5 °C (41
F)
•
MIN. WATER PRESSURE
1 atm. (15 PSI)
•
MAX. WATER PRESSURE
5 atm. (75 PSI)
•
MIN. AMBIENT TEMPERATURE
o
5 °C (41
F)
•
MAX. AMBIENT TEMPERATURE
o
40 °C (104
F)
•
MAX. VOLTAGE VARIATION
10%
•
o
C Evap. Temp (26,000
December 2000
Page 5
MAR1400 & MAR2000
Suggested Condensing Unit Settings
HEAD PRESSURE SETTING
15 Bar (218 PSIG) on air cooled and water
•
cooled units
LOW PRESSURE SETTING
1.6 Bar (23 PSIG) on air cooled units
•
HI-PRESSURE CONTROL SETTING
36 Bar (522 PSIG)
•
LO-PRESSURE CONTROL SETTING
0.2 Bar (3 PSIG)
•