Mar2000 - Scotsman MAR1400 User Manual

Scotsman mar1400 ice machine: user guide
Hide thumbs Also See for MAR1400:
Table of Contents

Advertisement

MAR2000

Set for Fresh water Operation
IMPORTANT OPERATING REQUIREMENTS:
WATER LEVEL IN DRUM RESERVOIR
115-120 mm (4.5 to 4.75 inches)
DRUM ROTATING SPEED
2.4 RPM (thick ice)
REFRIGERANT:
R-404A
REQUIRED CONDENSING CAPACITY
6500 Kcal/h at –24
o
BTUH at –11
F.)
WATER PRESSURE CONTROL SETTING
0.8 Bar (11 PSIG)
MAX. WATER TEMPERATURE
o
35 °C (95
F)
MIN. WATER TEMPERATURE
o
5 °C (41
F)
MIN. WATER PRESSURE
1 atm. (15 PSI)
MAX. WATER PRESSURE
5 atm. (75 PSI)
MIN. AMBIENT TEMPERATURE
o
5 °C (41
F)
MAX. AMBIENT TEMPERATURE
o
40 °C (104
F)
MAX. VOLTAGE VARIATION
10%
o
C Evap. Temp (26,000
December 2000
Page 5
MAR1400 & MAR2000
Suggested Condensing Unit Settings
HEAD PRESSURE SETTING
15 Bar (218 PSIG) on air cooled and water
cooled units
LOW PRESSURE SETTING
1.6 Bar (23 PSIG) on air cooled units
HI-PRESSURE CONTROL SETTING
36 Bar (522 PSIG)
LO-PRESSURE CONTROL SETTING
0.2 Bar (3 PSIG)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mar2000Mar1400rl-32aMar2000rl-32a

Table of Contents