MAR1400 & MAR2000

Installation

MAR SPLIT UNIT - UNPACKING AND
INSPECTION
1. Visually inspect the exterior of the shipping
container and skid. Any severe damage noted
should be reported to the delivery carrier and a
concealed damage claim filled subject to internal
inspection with the carrier representative present.
2. Remove the packing and remove the side
panels, then remove the shipping bolts securing
the unit to the skid.
3. Remove screws and all panels from cabinet and
inspect for any concealed damage. Notify carrier of
any concealed damage claims as stated in step 1
above.
4. Remove all internal packing from unit
compartment.
5. Check that refrigerant lines do not rub or touch
lines or surfaces and that all wires are securely
fastened to their terminals.
6. Use clean damp cloth or disposable paper towel
to wipe the exterior surface of the cabinet clean.
7. See DATA PLATE on the cabinet base and
check that the location source voltage corresponds
with the voltage specified on the data plate.
CAUTION - Improper voltage supplied to the
ice maker will void the warranty.
Water and
Refrigeration
Connection
Area
Electrical
Connection
Area
LOCATION AND LEVELING
1. Position the MAR SPLIT UNIT in the selected
permanent location which could be on top of ice
storage bins, on the side of cold storage room
supported by special pre-set stands or, in case of
fishing vessel installation, inside or on top of the
fish hold.
Note: See sales information for suggested bin
applications. Most will require the MAR unit to
be placed sideways on the bin's top.
See illustration at the bottom of this page.
2. After having placed the unit on the support
stand or bin, place thin rubber pads between the
ice machine base and the stand to level the
cabinet on both the left to right and front to rear
directions. There are holes in the base of the
cabinet, use them to secure the unit to the stand
with the appropriate (stainless steel) bolts.
Make sure to leave enough space around the unit
to allow access to internal components for
inspection and servicing and also for the fitting of
the ice chute.
3. If installing a separate condensing unit, position
the condensing unit in its location and to mount it
firmly to avoid a sudden shift that would endanger
the refrigerant lines. Precautions to be observed
vary with the kind of situation in which the unit is to
be placed. The area should be well ventilated to
permit escape of refrigerants in case unit develops
a leak.
MAR Unit
Chute
Top View of MAR on 60"w x 40"d bin
December 2000
Page 12