NME1850R & FME2400R
FOR THE PLUMBER
CONFORM TO ALL APPLICABLE CODES
Water Inlet
The recommended water supply is
WATER INLET
cold water. Use 3/8" O.D. copper
3/8" MALE
tubing, connect to the 3/8" male flare
FLARE
at the back of the cabinet. Install a
hand valve near the machine to
control the water supply.
FIELD
Drains
SUPPLIED
WATER FILTER
There is one 3/4" FPT drain at the
back of the cabinet, the drain line is of
HAND SHUT
the gravity type, and 1/4 inch per foot
OFF VALVE
fall is an acceptable pitch for the drain
VENT ICE
CONNECT TO
tubing. There should be a vent at the
MAKER
COLD WATER
highest point of the drain line, and the
DRAIN,
ideal drain receptacle would be a
3/4" FPT
trapped and vented floor drain. Use
only 3/4" rigid tubing.
Storage Bin: A separate gravity type
drain needs to be run. Insulation of
this drain line is recommended.
VENT BIN DRAIN
3/4" FPT
FLOOR DRAIN