COMPONENT DESCRIPTION: Control Box
Contactor: A definite purpose contactor
connecting the compressor and the remote
condenser fan motor to the power supply.
Circuit Board: Controlling the ice machine
through sensors and relays. The sensors are for
ice level and water level. The relays are for the
gear motor (with a built in time delay to clear the
evaporator of ice when the unit turns off) and for
the compressor contactor.
ON/OFF SWITCH
LOW
PRESSURE
CUT OUT
SWITCH
POTENTIAL
RELAY
TRANSFORMER
CIRCUIT
BOARD
NME1850 & FME2400
Transformer: Supplies low voltage to the circuit
board.
Low Pressure Cut Out Switch: A manual reset
control that shuts off the ice machine when the low
side pressure drops below a preset point, 0-4 psig.
Potential Relay : The compressor start relay.
On/Off Switch: Manual control for the machine.