Service Diagnosis: Components - Scotsman CME456R Product Manual

Scotsman cme456r ice machine: user guide
Hide thumbs Also See for CME456R:
Table of Contents

Advertisement

Service Diagnosis: Components

Problem or Symptom Possible Cause
Fan motor does not
turn.
Pump motor does not
turn
Hot Gas Valve does
not open.
Hot Gas Valve leaks
thru (warm tube
temperatures on both
sides of valve during
freeze)
Water Inlet Valve does
not open
Water Inlet Valve does
not flow enough water
Water Inlet Valve
leaks thru
Compressor does not
work
Open motor windings, or
seized bearings
No power to fan motor
Open motor windings, or
seized bearings
No power to pump
Open solenoid coil.
Stuck valve
No power to coil in Harvest
Mechanical problem in
valve
Open solenoid coil
Stuck valve
No power to valve (best
checked at the beginning
of Freeze)
Restriction in water supply
Mechanical problem in
valve
Unit in Clean cycle
Contactor coil open
Open starting components
Open windings
Internal valve failure
December 2000
Page 29
Probable Correction
Replace fan motor
Contactor may not close.
Replace pump
Check electrical connections. In Freeze, the
pump should have power to it. If not, replace
the AutoIQ Controller.
Replace hot gas valve
Replace hot gas valve
Check wire connections, if ok, replace AutoIQ
Controller
Replace valve
Replace valve
Replace valve
Check wire connections, if ok, replace AutoIQ
Controller
Check water filters and/or inlet screen.
Replace valve
Push and release Freeze button.
Replace contactor
Check and replace
Check and replace compressor
Replace compressor
CME456R