After Utility Connections - Scotsman CME456R Product Manual

Scotsman cme456r ice machine: user guide
Hide thumbs Also See for CME456R:
Table of Contents

Advertisement

After Utility Connections

1. Wash out the bin. If desired, the interior of the
bin could be sanitized.
2. Locate the ice scoop (if supplied) and have it
available for use when needed.
3. Switch on the electrical power. Do not start the
machine for 4 hours.
4. Go thru the final check list (below).
Final Check List:
___ 1.
Is the unit located indoors in a
controlled environment?
___ 2.
Has the correct remote condenser been
properly located and mounted?
___ 3.
Has the correct electrical power
(voltage and phase) been supplied to
the machine?
___ 4.
Have all the water supply connections
been properly made with the correct
size tubing?
___ 5.
Have all the drain connections been
properly made?
___ 6.
Has the unit been leveled? Level the
unit at the bin.
___ 7.
Have all unpacking materials been
removed?
___ 8.
Is the water pressure adequate?
___ 9.
Is the machine secured to the ice
storage bin?
___ 10. Is the bin control system been properly
installed?
___ 11. Have the drain connections been
checked for leaks?
___ 12. Has the bin interior been wiped clean or
sanitized?
___ 13. Have any water filter cartridges been
replaced?
___ 14. Check all refrigerant lines and conduit
lines, for vibration or rubbing and
possible failure. Adjust as needed.
___ 15. After 4 hours of electrical power,
proceed to Initial Start Up.
December 2000
Page 13
CME456R

Advertisement

Table of Contents
loading