Feig Electronic ID ISC.ANT1700/740-SLA Installation Manual
Feig Electronic ID ISC.ANT1700/740-SLA Installation Manual

Feig Electronic ID ISC.ANT1700/740-SLA Installation Manual

Clear gate
Table of Contents

Advertisement

Quick Links

INSTALLATION
ID ISC.ANT1700/740-SLA /-SLB
Clear Gate
English
final
public (B)
2010-10-11
M00210-2e-ID-B.doc

Advertisement

Table of Contents
loading

Summary of Contents for Feig Electronic ID ISC.ANT1700/740-SLA

  • Page 1 INSTALLATION ID ISC.ANT1700/740-SLA /-SLB Clear Gate English final public (B) 2010-10-11 M00210-2e-ID-B.doc...
  • Page 2 FEIG ELECTRONIC call explicit attention that devices which are subject of this document are not designed with components and testing methods for a level of reliability suitable for use in or in connection with surgical implants or as critical components in any life support systems whose failure to perform can reasonably be expected to cause significant injury to a human.
  • Page 3: Table Of Contents

    ® OBID i-scan Installation ID ISC.ANT1700/740-SLA/-SLB Contents Safety Instructions / Warning - Read before Start-Up ! Maintenance Performance Features of the ID ISC.ANT1700/740 SLx Antennas Performance Features of the People Counter ID ISC.ANT1700/740-GPC ....8 Available Antenna Types ..................11 Installation and Wiring Mounting preparation ....................
  • Page 4 6.3.3 Configuration and Test in Notification Mode ............55 Configuring the Reader in accordance with national RF regulations Technical Data Antenna ID ISC.ANT1700/740-SLA and -SLB ............59 People Counter ID ISC.ANT1700/740-GPC and ID ISC.ANT.GPC-E ...... 62 Approval ........................63 8.3.1 Europe (CE) ......................
  • Page 5 ® OBID i-scan Installation ID ISC.ANT1700/740-SLA/-SLB Safety Instructions / Warning - Read before Start-Up !  The device may only be used for the intended purpose designed by for the manufacturer.  The operation manual should be conveniently kept available at all times for each user.
  • Page 6 ® OBID i-scan Installation ID ISC.ANT1700/740-SLA/-SLB Maintenance The antenna ID ISC.ANT1700/740 is a design product with high quality surfaces, and should al- ways be handled with caution. The antenna was designed to work reliably and flawlessly for years without special maintenance.
  • Page 7: Performance Features Of The Id Isc.ant1700/740 Slx Antennas

    ID ISC.ANT1700/740-SLA/-SLB Performance Features of the ID ISC.ANT1700/740 SLx Antennas The ID ISC.ANT1700/740-SLA antenna is a version with 2 DynamicTuning Board ID ISC.DAT , Long Range Reader ID ISC.LRM2000-A, 8- times Multiplexer Module ID ISC.ANT.MUX M8 and additional signal light and buzzer already mounted.
  • Page 8: Performance Features Of The People Counter Id Isc.ant1700/740-Gpc

    ® OBID i-scan Installation ID ISC.ANT1700/740-SLA/-SLB 3.1 Performance Features of the People Counter ID ISC.ANT1700/740-GPC The product ID ISC.ANT1700/740-GPC, short form “Gate People Counter” or “GPC”, are made for mounting in the gate antennas ID ISC.ANT1700/740. A Gate People Counter consist of a People Counter board (PC) and one Radar Detector! The product ID ISC.ANT.GPC-E Extension Radar Detector is used to extend the People Counter to a...
  • Page 9 ® OBID i-scan Installation ID ISC.ANT1700/740-SLA/-SLB Radar Detection zone of a single gate Radar Detection zone with two aisles Counter 1 | Counter 2 Cnt. 1 | Cnt. 2 Cnt. 3 | Cnt. 4 | Out | Out Radar Detection zone with three aisles Radar Detection zone with four aisles Fig.
  • Page 10 ® OBID i-scan Installation ID ISC.ANT1700/740-SLA/-SLB There is no need of a direct connection from the GPC to the Host. All commands from the Host to the People Counters are embedded in the Pickyback Command of the reader. Normally, the host poll the GPC by sending protocols. Only, in the Notification Mode, the reader poll the counter values, automatically, and send data according the reader configuration to the host.
  • Page 11: Available Antenna Types

    ® OBID i-scan Installation ID ISC.ANT1700/740-SLA/-SLB 3.2 Available Antenna Types The following products are currently available: Antenna Type Description Picture ID ISC. ANT1700/740-SLA Antenna with Reader, Multiplexer , Clear Gate dynamic tuning board, signal light and buzzer ID ISC. ANT1700/740-SLB...
  • Page 12: Installation And Wiring

    ® OBID i-scan Installation ID ISC.ANT1700/740-SLA/-SLB Installation and Wiring Notes: Before installing the antennas please read 5.1 Project Notes . The spacing of the antennas in a gate depends on the antenna configuration. If multiple antennas or gates are connected to different readers, a minimum clearance of 8 m must be kept between the antennas or gates.
  • Page 13: Mounting Preparation

    ® OBID i-scan Installation ID ISC.ANT1700/740-SLA/-SLB 4.1 Mounting preparation For assembly the antenna must be carefully unpacked. This is done as described in the following steps: 1. Place the packed antenna on the floor with the top side facing up. Carefully open the box and then remove the antenna.
  • Page 14: Dimensions Of Antenna

    ® OBID i-scan Installation ID ISC.ANT1700/740-SLA/-SLB 4.2 Dimensions of antenna The outside dimensions of the antenna are shown in Fig. 5 Fig. 5: Antenna outside dimensions All dimensions are in mm with general tolerance to ISO 2768 m (mean). Fig. 6: Opening the antenna base...
  • Page 15: Drilling The Mounting Holes

    ® OBID i-scan Installation ID ISC.ANT1700/740-SLA/-SLB 4.3 Drilling the Mounting Holes If the position of the antennas has been marked or determined a hole template, can be used to mark and drill the mounting holes and the holes for the cable entry. The dimensions are shown in Fig.
  • Page 16 ® OBID i-scan Installation ID ISC.ANT1700/740-SLA/-SLB Alternatively the cables can be routed at the sides of the antenna bas like shown in Fig. 8 Fig. 8 Cable routing at the antenna sides FEIG ELECTRONIC GmbH Page 16 of 66 M00210-2e-ID-B.doc...
  • Page 17: Installing The Antenna Body

    ® OBID i-scan Installation ID ISC.ANT1700/740-SLA/-SLB 4.4 Installing the Antenna Body The antenna will be screwed on the floor. The transverse antenna conductors in the middle of the antenna body have to face the same direction at all antennas.(Fig. 9) Use the adjusting screws (Fig.
  • Page 18: Typical Antenna Configuration (Gate Antenna With Two Antennas)

    The standard configuration of a gate with three-dimensional tag orientation consists of one antenna ID ISC.ANT1700/740-SLA with reader and multiplexer and one antenna ID ISC.ANT1700740-SLB. If a tag moves, at horizontal line, through the gate, it can be read at least once. This ensures high reliability of the antenna system.
  • Page 19 ® OBID i-scan Installation ID ISC.ANT1700/740-SLA/-SLB To get a optimal performance the reader has to be configured and run in one of the Automatic Modes (Buffered Read, Notification or Scan Mode). If multiple gates are arranged with short distances (1-8m) between each other, these will mutually interfere with each other.
  • Page 20 ® OBID i-scan Installation ID ISC.ANT1700/740-SLA/-SLB Gate with antenna Type SLA and Type SLB  130 cm Gate distance GD Number of tags at a speed of 1 m/s Read serial number Read data Table 4: Design notes A minimum distance of 75cm between the two gate antennas is required.
  • Page 21: Gate Configuration And Setup Using Antennas Type -Sla And -Slb

    5.2 Gate Configuration and Setup using Antennas Type -SLA and -SLB 5.2.1 Required Components To construct the gate you need the following components: Qty. 1 ID ISC.ANT1700/740-SLA Clear Qty. 1 ID ISC. ANT1700/740-SLB Clear Qty. 1 ID ISC.NET24V-B Power Supply Unit...
  • Page 22: Configuration Of A Gate Antenna With Multiplexer

    ® OBID i-scan Installation ID ISC.ANT1700/740-SLA/-SLB 5.2.2 Configuration of a Gate antenna with Multiplexer Connect the components as shown in Fig. 12. .Almost, all cable should be mounted already. Normally, the antenna cable from antenna Type B has to be connected to OUT2 at the multiplexer and the 24V DC power supply to X11 of the terminal board only.
  • Page 23 ® OBID i-scan Installation ID ISC.ANT1700/740-SLA/-SLB Note:  A reverse polarity could damage the device or the In-/Outputs. The coax cables have fixed lengths and may not be shortened and therefore need to be tied into small loops (see Fig. 14). Tie all cables as far away from the antenna conductor as possible. The cables must never be allowed to contact the antenna conductor.
  • Page 24: Setting The Multiplexer

    ® OBID i-scan Installation ID ISC.ANT1700/740-SLA/-SLB 5.2.3 Setting the Multiplexer Set the jumpers JP11-JP18 shown. More on setting the ID ISC.ANT.MUX.M4 Multiplexer can be found in the corresponding installation manual (M90700-xde-ID-B). Fig. 16: Jumper positions FEIG ELECTRONIC GmbH Page 24 of 66...
  • Page 25: Setting The Antenna Tuner

    (hexagon socket width A/F2,5) at the antenna base cover and move it upwards. Fig. 17 Step 1 Step 2 Fig. 17: Opening of the antenna base The antennas ID ISC.ANT1700/740-SLA/SLB are factory set as follows: Table 5: Jumper settings for Antenna Tuner Function Jumper Position open 1...
  • Page 26: Interface Connections

    ® OBID i-scan Installation ID ISC.ANT1700/740-SLA/-SLB 5.2.5 Interface Connections 5.2.5.1 RS 232 The RS232 interface is connected on X8. The transmission parameters can be configured by means of software protocol. Pin configuration X8 (RS232 interface): Terminal Abbreviation Description RS232 – GND...
  • Page 27: Lan / Tcp/Ip

    ® OBID i-scan Installation ID ISC.ANT1700/740-SLA/-SLB 5.2.5.2 LAN / TCP/IP The Reader has an integrated 10/100Tbase network port for an RJ45. Connection is made on X11. With structured cabling Cat 5 cables should be used. This ensure reliable operation at 10Mbps or 100Mbps.
  • Page 28: Reader Configuration With Multiplexer

    ® OBID i-scan Installation ID ISC.ANT1700/740-SLA/-SLB 5.2.6 Reader Configuration with Multiplexer To tune the antennas, open the ISOStart software and read out the current configuration of the Reader: Step Action Note Start ISOStart Software Select „Detect“ Select „Keep Configuration unchanged and exit Wizard“...
  • Page 29 ® OBID i-scan Installation ID ISC.ANT1700/740-SLA/-SLB Step Action Note Select „Expert Mode“ and confirm with OK. Select “Logical View” FEIG ELECTRONIC GmbH Page 29 of 66 M00210-2e-ID-B.doc...
  • Page 30 ® OBID i-scan Installation ID ISC.ANT1700/740-SLA/-SLB Then set the operating power, Transponder Parameters and ISO Host Mode: Step Action Note Select “Configuration” Air Interface: “RF-POWER” (here 4W) „Mulitplexer Enable“ „1 Input (Single Mode)“ „No of Output Channels „ (e.g. 4) „Antenna Active Time“...
  • Page 31: Tuning The Gate Antenna With Multiplexer

    ® OBID i-scan Installation ID ISC.ANT1700/740-SLA/-SLB 5.2.7 Tuning the Gate Antenna with Multiplexer Before tuning the gate antenna, you must quit the ISOStart software. Then the gate can be tuned as follows: Step Action Note Start “DATuningTool” software Select “Detect Reader...”.
  • Page 32: Testing The Gate Antenna

    ® OBID i-scan Installation ID ISC.ANT1700/740-SLA/-SLB 5.3 Testing the Gate Antenna After tuning the gate antenna, you can check for proper function using a Reader, the ISOStart service software and a Transponder. Here the Noise Level and performance of the gate are tested.
  • Page 33 ® OBID i-scan Installation ID ISC.ANT1700/740-SLA/-SLB Step Action Note Select „Function Unit Command“ „Multiplexer“ „Channel Select“ activate antenna 2. „Cascade Level = 1“ „Output Channel of Input 1 = 2“ Set by clicking on „Send“. Repeat step 3 to 5 for antenna 2, 3, 4.
  • Page 34: Reading A Serial Number

    ® OBID i-scan Installation ID ISC.ANT1700/740-SLA/-SLB 5.3.2 Reading a Serial Number Step Action Note Attach a tag to an antenna Use adhesive tape, for example Activate antenna 1 with command: „Function Unit Commands - Multiplexer“ Parameter: „Channel Select“ „Cascade Level = 1“...
  • Page 35: Testing The Performance

    ® OBID i-scan Installation ID ISC.ANT1700/740-SLA/-SLB 5.3.3 Testing the performance For testing the performance you have to switch the reader to one of the Automatic Modes. (See 5.5 Activating the Automatic Mode) A read transponder will be displayed by a blue LED on the reader or by the LED light of the antenna.
  • Page 36 ® OBID i-scan Installation ID ISC.ANT1700/740-SLA/-SLB   The test begins by checking the read range outside the gate (see Fig. points ), assuming the configuration and locality permit it. Start the ISO Inventory command in the ISOStart program as described in 5.3.2 Reading a Serial...
  • Page 37: Connecting And Setting The Alarm Kit (Optional)

    ® OBID i-scan Installation ID ISC.ANT1700/740-SLA/-SLB 5.4 Connecting and Setting the Alarm Kit (optional) The solution provided here presumes that the alarm indicator (buzzer) is switched through the digital-output 1 /X6 and the LED light through the relay 1 /X11 on the ID ISC.LRM2000-A reader.
  • Page 38: Reader Setting For Indicator

    ® OBID i-scan Installation ID ISC.ANT1700/740-SLA/-SLB 5.4.1 Reader Setting for Indicator The ISOStart software can be used to set the Reader configuration so that output 1 X6-1/-2 or relay X11 opens or closes when a Transponder is read. Step Action...
  • Page 39: Programming A Transponder With The Afi Byte

    ® OBID i-scan Installation ID ISC.ANT1700/740-SLA/-SLB 5.4.2 Programming a Transponder with the AFI Byte If the Transponders will remain on the object when leaving the storage location, they must first be cancelled. This is generally done by writing to a particular area of the Transponder.
  • Page 40 ® OBID i-scan Installation ID ISC.ANT1700/740-SLA/-SLB To verify, read AFI byte by using the command [0x2B] Get System Information FEIG ELECTRONIC GmbH Page 40 of 66 M00210-2e-ID-B.doc...
  • Page 41: Activating The Automatic Mode

    ® OBID i-scan Installation ID ISC.ANT1700/740-SLA/-SLB 5.5 Activating the Automatic Mode The gate must be used in one of the Automatic Modes (Buffered Read, Notification or Scan Mode) to get a maximum performance. Which Mode is useful in your application, has to be defined in advance.
  • Page 42: Installation Of The Gate People Counter Id Isc.ant1700/740-Gpc

    ® OBID i-scan Installation ID ISC.ANT1700/740-SLA/-SLB Installation of the Gate People Counter ID ISC.ANT1700/740-GPC 6.1 Installation and Connections Content of the 1 piece mounting bracket ID ISC.ANT1700/740-GPC 1 piece Radar connection cable 1 piece connection cable People Counter –Terminal board.
  • Page 43 ® OBID i-scan Installation ID ISC.ANT1700/740-SLA/-SLB Step Action Note Attention !! Note: Do not touch the an- tenna surface of the Radar module to avoid damaging the electronic components and soiling. Set sensitivity of Radar sensor by setting jumper J1 and J2.
  • Page 44 ® OBID i-scan Installation ID ISC.ANT1700/740-SLA/-SLB Connect one plug of radar connection cable with X1 of Radar module. Here: yellow/white/green/brown The other plug will be used for the second radar sensor, in case of a gate with two aisle. Install the mounting bracket in the antenna with 4 pieces.
  • Page 45 ® OBID i-scan Installation ID ISC.ANT1700/740-SLA/-SLB Fix the cable with the cable clips beside the coax cable. Install People Counter Board with the hexagon spacers and the screws into antenna foot beside the multiplexer. FEIG ELECTRONIC GmbH Page 45 of 66...
  • Page 46 ® OBID i-scan Installation ID ISC.ANT1700/740-SLA/-SLB Plug Radar connection ca- ble onto X11 Sen 1 Here: yellow/white/green/brown The other plug should be connected to X12 Sen 2, but has no function at the use of only one radar sen- sor.
  • Page 47 ® OBID i-scan Installation ID ISC.ANT1700/740-SLA/-SLB Connect RS485 cable to X7 of reader. Plug 5 pin connection plug onto X13/GPC-OUT of Terminal Board. Installing the People Counter at antennas Type B The installation must be done in the same way like at the antenna Type A.
  • Page 48 ® OBID i-scan Installation ID ISC.ANT1700/740-SLA/-SLB Radar module ID ISC.ANT1700/740-GPC Long Range Reader ID ISC.LRM2000-A Gate People Counter ID ISC.ANT1700/740-GPC LED3 LED2. 3.Antenna 1. Antenna Second GPC 4. Antenna (Type SLB) Fig. 21: Connections ID ISC.ANT1700/740-GPC FEIG ELECTRONIC GmbH Page 48 of 66...
  • Page 49: Installation Id Isc.ant.gpc-E

    ® OBID i-scan Installation ID ISC.ANT1700/740-SLA/-SLB 6.2 Installation ID ISC.ANT.GPC-E Content of the ID ISC.ANT.GPC-E 1. 1 piece Radar connection cable 2. 1 piece Radar module 3. 2 piece Jumper 4. 2 piece spilt rivet 3,0mm 5. 1 piece cable-clip...
  • Page 50 ® OBID i-scan Installation ID ISC.ANT1700/740-SLA/-SLB Install Radar module with split rivet 3,0mm at the back of the mounting bracket Connect second plug of radar connection cable with X1 of Radar module. Here: red/Grey/blue/pink Plug second plug of Radar connection cable onto X12...
  • Page 51 ® OBID i-scan Installation ID ISC.ANT1700/740-SLA/-SLB Radar Module Radar Module ID ISC.ANT.GPC-E ID ISC.ANT1700/740-GPC Gate People Counter ID ISC.ANT1700/740-GPC Fig. 1 Connections GPC-E 2.Radarmodule FEIG ELECTRONIC GmbH Page 51 of 66 M00210-2e-ID-B.doc...
  • Page 52: Configuration And Test

    ® OBID i-scan Installation ID ISC.ANT1700/740-SLA/-SLB 6.3 Configuration and Test To activate the People Counters the following settings hast o be done. Set additional the Jumpers JP1,2 and 5 at X700 of Reader ID ISC.LRM2000-A to configure the RS485. Fig. 2 (see also manual M51001-2de-ID-B , page 43 and 44) Fig.
  • Page 53: Connecting Several People Counter

    ® OBID i-scan Installation ID ISC.ANT1700/740-SLA/-SLB 6.3.1 Connecting several People Counter If you have to use several People Counters (max. up to 3) you could connect them parallel at the Terminal Board. For the connection you must use 5 pin shielded, twisted-pair cable. Example:...
  • Page 54: Configuration And Test In Iso-Host Or Buffered Read

    ® OBID i-scan Installation ID ISC.ANT1700/740-SLA/-SLB 6.3.2 Configuration and Test in ISO-Host or Buffered Read Step Action Note Select „Configuration“ Peripheral Devices/CFG8 Set People Counter to„True“ Confirm with „Apply“ Select Command - „Get Reader Info“ - Peripheral Devices Confirm with „Send“...
  • Page 55: Configuration And Test In Notification Mode

    ® OBID i-scan Installation ID ISC.ANT1700/740-SLA/-SLB Walk through the gate from both directions. Counter 1 | Counter 2 | Out Select Command „Get People Counter Values“ Confirm with „Send“ Counter values will be displayed. In ISO-Host or Buffered Read the People Counter has to be polled by the Host Application to get the data.
  • Page 56 ® OBID i-scan Installation ID ISC.ANT1700/740-SLA/-SLB Operating Mode Select -Notification Mode Confirm with „Apply“ Set IP Address and Port for Notification Mode IP Address of Host e.g. here : 192.168.3.213 Port:20005 Set IP Address and Port for People Counter IP Address of Host e.g.
  • Page 57: Configuring The Reader In Accordance With National Rf Regulations

    ® OBID i-scan Installation ID ISC.ANT1700/740-SLA/-SLB Configuring the Reader in accordance with national RF regulations Configuration of the RFID Readers and the maximum transmitting power of the antennas are affected mainly by the country-specific RF regulations. For the entire EU the limits are set forth in the R&TTE Directive and EN 300 330.
  • Page 58 ® OBID i-scan Installation ID ISC.ANT1700/740-SLA/-SLB The Reader needs to be configured as follows depending on the installation location: Parameter Europe (60dBuA/m) Air Interface RF-Power: maximum 4 W RF Modulation: Transponder Parameters RF Modulation / ISO-MODE / RF Data coding ISO-MODE:...
  • Page 59: Technical Data

    ® OBID i-scan Installation ID ISC.ANT1700/740-SLA/-SLB Technical Data 8.1 Antenna ID ISC.ANT1700/740-SLA and -SLB Mechanical Data  Housing UV stabilized ABS  Dimensions ( W x H x D ) – Antenna 741 mm x 1700 mm x 76 mm  3 mm –...
  • Page 60 ® OBID i-scan Installation ID ISC.ANT1700/740-SLA/-SLB  Maximum transmitting power per antenna  Permissible overall transmitting power per antenna gate – EU-territory (per EN 300 330) and other CEPT nations  Outputs – 1 Optocoupler 24 V / 30 mA –...
  • Page 61 EN 50364 * Persistent deformation after load release approx. 1 cm. ** Qty. 2 ID ISC.ANT1700/740-SLA/-SLB antennas, antenna spacing (antenna center), same flow direction, Tag 46 mm x 75 mm ISO15693, sensitivity / minimum field strength H =60 / 40 mA/m rms, transmitting power 8 W, tag orientation parallel to antenna for horizontal movement through the antenna.
  • Page 62: People Counter Id Isc.ant1700/740-Gpc And Id Isc.ant.gpc-E

    ® OBID i-scan Installation ID ISC.ANT1700/740-SLA/-SLB 8.2 People Counter ID ISC.ANT1700/740-GPC and ID ISC.ANT.GPC-E Mechanical Data  Housing Printed Boards  Board Dimensions ( B x H x T ) 100 mm x 40 mm x 16 mm  1 mm –...
  • Page 63: Approval

    Equipment Classification according to ETSI EN 300 330 and ETSI EN 301 489: Class 1 The technical data of the ID ISC.LRM2000 Reader built into the ID ISC.ANT1700/740-SLA antenna can be found in the Installation Manual which is included with the device.
  • Page 64: Usa And Canada (Ul)

    ® OBID i-scan Installation ID ISC.ANT1700/740-SLA/-SLB 8.3.2 USA and Canada (UL) The following picture indicates the label position: FEIG ELECTRONIC GmbH Page 64 of 66 M00210-2e-ID-B.doc...
  • Page 65 ® OBID i-scan Installation ID ISC.ANT1700/740-SLA/-SLB Annex A Terminal Acronym Description X1 / LR 24V DC Reader X1 / Pin 1 +24 V DC Reader X1 / Pin 2 GND Reader X2 / I/O 24V DC Input/Output X2 / Pin 1...
  • Page 66 ® OBID i-scan Installation ID ISC.ANT1700/740-SLA/-SLB X12 / Pin 2 GND LED2 X13 / GPC-out Connection Cable to 2. People Counter X13 / Pin 1 +24 V DC People Counter 2 X13 / Pin 2 GND People Counter 2 X13 / Pin 3...

This manual is also suitable for:

Id isc.ant1700/740-slb

Table of Contents