APPLICATION-NOTE
®
OBID i-scan
ID ISC.MR200-E
How to change the TCP/IP address
preliminary
public (B)
2004-09-20
N40901-0e-ID-B.doc

Advertisement

loading

Summary of Contents for Feig Electronic OBID i-scan ID ISC.MR200-E

  • Page 1 APPLICATION-NOTE ® OBID i-scan ID ISC.MR200-E How to change the TCP/IP address preliminary public (B) 2004-09-20 N40901-0e-ID-B.doc...
  • Page 2 Composition of the information in this document has been done to the best of our knowledge. FEIG ELECTRONIC GmbH does not guarantee the correctness and completeness of the details given in this manual and may not be held liable for damages ensuing from incorrect or incomplete information.
  • Page 3 ID ISC.MR200-E Content 1. Safety Instructions / Warning - Read before start-up ! ..............4 2. Introduction............................. 5 3. Installation of Digi Device Discovery .................... 6 4. Change the TCP-IP address ......................6 FEIG ELECTRONIC GmbH Page 3 of 7 N40901-0e-ID-B.doc...
  • Page 4: Safety Instructions / Warning - Read Before Start-Up

    Use of the device and its installation must be in accordance with national legal requirements and local electrical codes . • When working on devices the valid safety regulations must be observed. FEIG ELECTRONIC GmbH Page 4 of 7 N40901-0e-ID-B.doc...
  • Page 5: Introduction

    This description describes how the TCP/IP address can be configured on the ID ISC.MR200-E reader using the tool “Digi Device Discovery (dgdiscvr.exe)”. Later reader versions will be able to change the TCP/IP address by using the demo program ID ISOStart. ID ISC.MR200-E FEIG ELECTRONIC GmbH Page 5 of 7 N40901-0e-ID-B.doc...
  • Page 6: Installation Of Digi Device Discovery

    2. Start the program “Digi Device Discovery” by double click onto “dgdiscvr.exe” 3. The following window appears and the program shows the current default TCP/IP address (192.168.10.10) of the reader. 4. If the reader has been detected press the button “Configure network settings”. FEIG ELECTRONIC GmbH Page 6 of 7 N40901-0e-ID-B.doc...
  • Page 7 7. After the process has been finished the new TCP/IP address should be displayed. 8. Close the program “Digi Device Discovery” and check the function using the ID ISOStart program or any other program which support the TCP/IP interface. FEIG ELECTRONIC GmbH Page 7 of 7 N40901-0e-ID-B.doc...