Page 1
*26864967_0321* Drive Technology \ Drive Automation \ System Integration \ Services Addendum to the Operating Instructions Local Keypad CBG22A Local Operating Unit with Diagnostics, Manual Mode and Process Data Interface Edition 03/2021 26864967/EN...
Structure of section-related safety notes Section-related safety notes do not apply to a specific action but to several actions pertaining to one subject. The hazard symbols used either indicate a general hazard or a specific hazard. Addendum to the Operating Instructions – CBG22A...
Example nameplate of a local keypad ................ 16 Electrical installation...................... 17 PC connection....................... 17 Startup ............................. 18 Process data ......................... 18 Process data configuration ................... 19 Process data description.................... 21 Technical data and dimension sheets .................. 26 Technical data....................... 26 Addendum to the Operating Instructions – CBG22A...
USB 2.0 Mini B interface, female (PC connection) Lock D-Sub interface, 9-pin, female Nameplate Info key (for information about the selected menu) Keys The following figure shows the required keys of the CBG22A local keypad: Key 1 " " Key 2 " " Key 3 " "...
Operating modes Operating modes The CBG22A local keypad has 2 operating modes: direct control mode and indirect control mode. You can switch between the two operating modes by means of process data. The table below lists the main differences between the two operating modes.
Page 8
All screens except for manual mode serve only for diagnostic purposes. No parame- ters, with the exception of a fault reset, can be written to the drive but can only be read. Addendum to the Operating Instructions – CBG22A...
Page 9
Actuating the key switch opens the monitoring screen. All screens except for the monitoring screen serve only for diagnostic purposes. No parameters, with the exception of a fault reset, can be written to the drive but can only be read. Addendum to the Operating Instructions – CBG22A...
The display of the local keypad shows the selectable functions in the form of icons. Icon Meaning Start menu Monitoring ® MOVISAFE CS.. DIP switch Process data Digital inputs/outputs Operating and energy data Device information Fault memory Gateway operation Settings Addendum to the Operating Instructions – CBG22A...
Page 11
Device structure Representations and functions Icon Meaning Main menu Manual mode Direct control mode active Indirect control mode active Addendum to the Operating Instructions – CBG22A...
Page 12
In indirect control mode, users can change the background color, display a free text, and adjust the brightness in this menu. In addition, the keystrokes are evaluated in this menu and passed on to the higher-level controller for processing. Addendum to the Operating Instructions – CBG22A...
Page 13
Momentary function: The drive moves only as long as the "RUN CW" or "RUN CCW" key has been pressed (jog mode). The brake can be released or applied manually by pressing the first function key from the left. Addendum to the Operating Instructions – CBG22A...
Page 14
2.3.5 Key switch function The key switch is essential for using the CBG22A local keypad. Manual mode is activated solely by the position of the key switch in direct control mode. Activating the key switch in indirect control mode opens the monitoring screen.
Page 15
0 = 0) Manual mode screen opens Monitoring Drive is directly screen opens controlled by CBG22A Key switch Key switch continues to be continues to be active? active? Last opened menu displayed 34036798347 Addendum to the Operating Instructions – CBG22A...
Firmware status Hardware status Unique serial number Part number and status Type designation 2.4.2 Type designation The following table shows an example type designation of the CBG22A local keypad: Type designation Description Part number Generation C keypad option 28277554 Local keypad Version Addendum to the Operating Instructions –...
PC connection The following figure shows an example of how to connect the PC to the local keypad of MOVIMOT® flexible MMF3..: 34184949515 USB/MINI USB B connection cable (commercially available, high-speed type) CBG22A local keypad Addendum to the Operating Instructions – CBG22A...
Startup Process data Startup Process data The following process output data (PO) and process input data (PI) are available for data exchange between the higher-level controller (PLC) and the CBG22A local keypad: Indirect control mode Function Control word PO1 Control word 1 (required)
2. In the parameter tree of the inverter, select parameter number 4.2.24 "Transparent mode" [1]. 3. Assign the required process output data words [2] of the inverter to the control words 1 to 3 of the transparent mode. 9007225901804299 Addendum to the Operating Instructions – CBG22A...
Page 20
2. In the parameter tree of the inverter, select parameter number 4.3.1 "PI data" [1]. 3. Assign status words [0] and [1] of transparent mode to the respective process in- put data words [2] of the inverter. 9007226995700875 Addendum to the Operating Instructions – CBG22A...
Pressing any key makes the display return to normal brightness. 0 1 Level 1 brightness selected. 1 0 Level 2 brightness selected. 1 1 Level 3 brightness selected. 1) The CBG22A local keypad does not have key LEDs. 2) Dimming is disabled. Addendum to the Operating Instructions – CBG22A...
Page 22
Position for ASCII code in the display memory (usable memory area: 32 bytes) Position for UNICODE in the display memory (usable memory area: 64 bytes) L = Low byte of the UNICODE character H = High byte of the UNICODE character Addendum to the Operating Instructions – CBG22A...
Page 23
0x00 – 0xFF High byte: Position of the character in the display memory (see chapter "Character position depending on character code). Low byte: ASCII or UNICODE character code 0xFB – 0xFF 0x00 – 0xFF Reserved Addendum to the Operating Instructions – CBG22A...
Page 24
Key 7 "RUN" Key 7 "RUN" not pressed. Key 7 "RUN" pressed. Mode Bits Description 15 14 0 0 Indirect control mode is not active. 0 1 Indirect control mode is active. 1 0 Reserved 1 1 Reserved Addendum to the Operating Instructions – CBG22A...
Page 25
Indirect control mode status word [1] High byte Low byte Description 0x00 – 0xFF 0x00 – 0xFF Status word [1] equals control word 2 as soon as in- direct control mode control word 2 has been received successfully. Addendum to the Operating Instructions – CBG22A...
Technical data and dimension sheets Technical data Technical data and dimension sheets Technical data 5.1.1 Technical data of the CBG22A local keypad Local keypad CBG22A Part number 28277554 Interfaces D‑sub, 9‑pin, female (CAN interface) USB 2.0 mini B, female (PC connection) Display IPS panel, 320 × 240 pixels, 2.4"...