Hi-Flame Precision II HF907-SE Instruction Manual

Free-standing multi fuel non-boiler stove

Advertisement

Quick Links

®
P recision II
• • • •
Instruction Manual
Model Precision II HF907-SE
Free-standing Multi Fuel Non-Boiler Stove
Published July 2012
Please note This appliance must, at all times, be operated in
accordance with the instructions to minimise the amount of
smoke produced.
You will need to refer to the serial number of your stove
shown above should you ever need to make a claim under
the Precision Warranty. You will also find the serial number,
beginning with HF, on the CE plate at the rear of the stove as
well as on the lid of the outer packaging.
Write the date the stove was delivered to you below as this is
likely to differ from the purchase date.
-
-
www.hi-flame.com
Ref: HF907-SE / UK-NI-ROI / V1-D.01-07-12
Precision II Non-Defra Handbook.indd 1
9/7/12 14:53:15

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Precision II HF907-SE and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Hi-Flame Precision II HF907-SE

  • Page 1 ® P recision II • • • • Instruction Manual Model Precision II HF907-SE Free-standing Multi Fuel Non-Boiler Stove Published July 2012 Please note This appliance must, at all times, be operated in accordance with the instructions to minimise the amount of smoke produced.
  • Page 2: Table Of Contents

    Routine Checks This instruction manual is also used for Standing Down a number of other stove models in the Hi-Flame product range and therefore Routine Maintenance some of the stove photographs and Annual Service diagrams used, which are used for...
  • Page 3: Dimensions

    IMPORTANT STANDARD FEATURES DIMENSIONS 1 Primary Air Control Air which enters In the interests of safety please read these instructions carefully under the grate for burning multi fuels, before installing or operating (other than wood). Also used at the your new stove. Even if you have beginning of wood fires installed or operated stoves before, 2 Pre-heated Secondary Air...
  • Page 4 TECHNICAL DATA INTRODUCTION Thank-you for purchasing the Precision II stove. We are confident GENERAL SPECIFICATION MINIMUM DISTANCES TO that with its state-of-the-art COMBUSTIBLE MATERIALS Model Name Precision II combustion technology it will warm Rear 300 mm your home even on the coldest Model Number HF907-SE winter days and provide you with...
  • Page 5: Installation Regulations

    INSTALLATION Other Information Points IMPORTANT SAFETY ADVICE • To ensure your safety make sure that your stove’s installation complies with REGULATIONS The Solid Fuel Association website is • Ensure that an approved carbon all local building regulations’ ventilation a very good source of practical monoxide detector (BS EN50291:2001) You must ensure that your stove is requirements.
  • Page 6: Assembling The Stove

    ASSEMBLING THE STOVE this plate should sit securely on a small For a top flue outlet remove the loose Always use the correct sized Phillips ledge at the back of the firechamber, fitted stove lid and unfasten the crosshead screwdriver and be careful Your new Precision stove is extremely towards the top.
  • Page 7: Smoke Control Areas

    YOUR LEGAL OBLIGATIONS RECOMMENDED FUELS Further information on the – the time between refills. All of this is requirements of the Clean Air Act can providing it is fully seasoned wood. IF YOU LIVE IN A UK The Alpha II AL907-SE stove allows the be found at the following website: SMOKE CONTROL AREA...
  • Page 8: Important: First Fires

    PROHIBITED FUELS UNDERSTANDING HOW IMPORTANT: FIRST FIRES content used in their production which will also leave harmful residue inside the DIFFERENT FUELS BURN Never use your stove like an incinerator. Use smaller and shorter ‘gentle’ fires stove and flue system. Burning prohibited ‘fuels’...
  • Page 9: Burning Wood Logs

    BURNING WOOD LOGS 1 Kindling This is generally finely 2 The First Refuel Phase chopped wood, approximately 5 to For best results: As previously stated wood burns best 10mm thick (1/4” to 1/2”) from your After 10 minutes on a bed of its own embers which also supply of logs.
  • Page 10 are the better the wood is burning. Never overfill the firechamber and also to avoid overloading the fire chamber. If the log surface is predominately avoid over-sized pieces of wood which Operating in a Smoke Control Area black and / or the flames are a dull will ‘slow’...
  • Page 11: Burning Mineral Fuels

    BURNING MINERAL FUELS SOME SIMPLE TIPS maintain the temperature inside the quickly established without ‘damping’ firechamber. At the beginning of the the fire. Do not use in a Smoke Control Area 1 When refuelling use small regular lighting stage the grate should always Re-adjust the air settings once all the unless it is an Approved Smokeless Fuel loads as this will produce a more...
  • Page 12: Installation Check-List

    REMOVING ASH INSTALLATION limit the Primary air flow and cause excessive heat build-up which could CHECK-LIST Wood will produce a lot less ash than eventually warp or burn out the grate. multi fuels and it would not be This information is intended to outline Locate the operating tool in the slot at unrealistic to expect to empty the ash the general principles of installing your...
  • Page 13 • The fireplace recess or opening is regulations, whichever is the greater. A for the stove which are outlined in this the stove will allow the stove to suitably constructed and conforms to combustible material is anything which handbook. The hearth should extend radiate heat and circulate warm air all applicable building regulations and can burn once it gets hot enough and...
  • Page 14 top of the hearth base to the top of the hatches in the system. lime mortar, eventually causing bfcma, produces an authoritative and informative download Yellow Guide to chimney terminal is 4.5m (15’). If this is unsightly stains on decorative coverings. Since stoves create flue gases at a much not possible then a ‘spinner’...
  • Page 15 COMMISSIONING TROUBLE-SHOOTING STOVE, FLUE OR OTHER therefore that your flue system, COMPONENTS GLOWING RED chimney closure (registration) plate 1 Confirm that all internal parts of the CHIMNEY FIRE and chimney has as many cleaning • Prevention stove are correctly fitted, including the If your stove has been installed access points as practicable to enable The Primary and Secondary air controls...
  • Page 16 STOVE NOT PROVIDING situation you should take immediate combustion air and the advice of the of the air controls so that the fire burns ENOUGH HEAT avoiding action. original installer should be sought. with very strong bright yellow flames and with very little difference when •...
  • Page 17 • Causes: Air Controls Ensure that ROUTINE CHECKS STANDING DOWN controls make to the performance of you fully understand how the Airwash the stove and the best way to burn your During routine checks if you notice There will be some point in the year type of fuel.
  • Page 18: Routine Maintenance

    ROUTINE MAINTENANCE inside the stove. If necessary small is thoroughly dry as any residue can be sure the stove is cold and use protec- cracks can be repaired using a ‘baked’ on causing unsightly smearing. tive gloves as this type of polish can •...
  • Page 19 ANNUAL SERVICE Door Seal Check that this continues Date FIRST SERVICE to make an air-tight seal and replace In the interests of safety it is important if necessary. Ensure that the new rope Work carried out: Next Service Due that your Precision stove is serviced on joint is also in the middle at the base an annual basis in accordance with the of the rope seal channel.
  • Page 20 Precision WARRANTY Precision guarantee that your product will be free from defective parts, Your new stove has been CE tested in materials and workmanship at the time the UK to ensure that it meets strict of purchase by the original consumer constructional, performance and safety for a period of 1 year for components standards.
  • Page 21 Manor Lane Holmes Chapel Cheshire CW4 8AF © Hi-Flame 2007, 2008, 2009, 2010, 2011 and 2012 All rights reserved. Booklet contents may not be copied in whole or in part without the prior written permission of the copyright holder. Hi-Flame is the original trading and www.hi-flame.com...

Table of Contents