4. REFRIGERANT FLOW DIAGRAM

4-1. Refrigerant Flow Diagram
Outdoor Unit CM1972
Indoor unit
Wide tube
O.D.3/8"
O.D.3/8"
O.D.3/8"
Narrow tube
O.D.1/4"
O.D.1/4"
O.D.1/4"
Insulation of Refrigerant Tubing
IMPORTANT
Because capillary tubing is used in the outdoor unit, both the
wide and narrow tubes of this air conditioner become cold. To
prevent heat loss and wet floors due to dripping of
condensation, both tubes must be well insulated with a
proper insulation material. The thickness of the insulation
should be a min.5/16"(8 mm).
After a tube has been insulated,
never try to bend it into a narrow
CAUTION
curve because it can cause the tube
to break or crack.
Outdoor unit
Service valve on
wide tube
CW
BW
AW
Header
Electric
expansion
valve
Service valve on
narrow tube
M
CN
M
BN
M
AN
Strainer
19
Sub
Main
accumulator
accumulator
High pressure
switch
H.P.
Header
Thickness:
Min.5/16"(8 mm)
Wide tube
Cooling cycle
Insulation
Thickness:
Min.5/16"(8 mm)
Narrow tube