5.3 Mains connection
The equipment you have purchased comes with
an earthing-pin plug. The equipment is designed
for connection to a socket outlet with earthing
contact for 230 V ~ 50 Hz. Make sure that the
socket-outlet is suffi ciently fused (at least 6 A)
and in good working order. Insert the power plug
in the socket-outlet and the equipment is ready
for operation.
Important!
To rule out danger, this work must be left strictly to
a specialist electrician or Customer Service.

6. Operation

You can put the equipment into operation after
you have thoroughly read the installation and ope-
rating instructions. Pay attention to the following
points:
Make sure that the equipment is set up secu-
rely.
Check that the discharge line is fitted correct-
ly.
Make sure that the electrical connection is
230 V ~ 50 Hz.
Check that the electrical socket-outlet is in
good working order.
Make sure that no moisture or water can ever
reach the power connection.
Make sure that the equipment does not run
dry.
Function of the integrated fl oating switch
Automatic mode:
Selector switch (A) must be in the lower position
during automatic mode (Fig. 4).
This activates the integrated fl oating switch. The
height of activation is approximately 12 cm. The
equipment switches off again when a height of
approximately 3 cm is reached.
Manual mode/shallow water:
Selector switch (A) must be in the upper position
to operate manually or in shallow water (Fig. 5).
This bridges the integrated fl oating switch so that
the equipment runs continuously. Water can be
pumped down to 2 mm in manual mode.
Anl_GE_SP_750_LL_SPK7.indb 16
Anl_GE_SP_750_LL_SPK7.indb 16
GB
Please note:
The depth of water must be at least 50 mm before
the equipment can be run in manual mode!
Important.
The equipment must not run dry!

7. Replacing the power cable

Danger!
If the power cable for this equipment is damaged,
it must be replaced by the manufacturer or its
after-sales service or similarly trained personnel
to avoid danger.
8. Cleaning, maintenance and
ordering of spare parts
Important!
Unplug the power plug prior to any mainte-
nance work.
For mobile applications, the equipment
should be cleaned with clear water after every
usage.
For stationary installation, it is recommended
that you check the floating switch for proper
functioning every three months.
Use a water jet to remove any lint or fibrous
particles that may have become trapped in
the housing.
Remove sludge from the shaft bottom and
clean the shaft walls every 3 months.
Use clear water to remove deposits from the
floating switch.
8.1 Cleaning the paddle wheel
If a lot of deposits collect in the housing, the bot-
tom part of the equipment must be dismantled as
follows:
1. Disconnect the intake cage from the housing.
2. Clean the paddle wheel with clear water.
Important! Do not put down or rest the equip-
ment on the paddle wheel!
3. Assemble in reverse order.
8.2 Maintenance
There are no parts inside the equipment which
require additional maintenance.
- 16 -