Advertisement

Connecting 120  V AC Loads to the Generator
Calculate Power Draw:
Power draw can be calculated by multiplying volts and amps. The resulting number is wattage.
• Never exceed the running wattage for the Generator or any outlet amperage rating.
• Refer to appliance/tool owner's manuals to determine the wattage of electrical load devices.
• Long power cords and extension cords draw additional power. Keep cord length at a minimum.
Wattage Estimates
Refer to your device documentation for start-up and running wattage requirements.
Check nameplate wattages on all loads before connecting to Generator.
Plug the power cord of the 120 volt appliance/tool into the 120  V AC Outlet
on the Generator. Plug in appliances from largest to smallest load.
Note: Do not allow the Generator to completely run out of fuel with
devices attached. A Generator's output may sharply spike as it runs
out of fuel, causing damage to attached devices.
Overload Indicator
Note: The OVERLOAD light may turn on for a few seconds as a large device starts up.
This is normal for loads approaching the capacity of this Generator.
1. The total combined load through the outlet on the Generator must not exceed the running power of the unit.
2. When approaching maximum running power, the OVERLOAD light will blink. If the OVERLOAD
light turns on continuously and the Generator stops producing power, it has been overloaded.
3. Turn off and disconnect all electrical devices. Compare device requirements to Generator rating and reduce the
total wattage of connected devices if necessary. Move anything that may be limiting Generator ventilation away.
4. Check if any circuit breakers have tripped and make sure that ALL circuit breakers are reset.
5. Press the OVERLOAD RESET button to restore Generator power output and
reconnect devices while being careful to not overload Generator.
Low Oil Indicator
1. If the Engine oil level is too low, the LOW OIL light turns on and the Engine will automatically shut off.
2. The Engine cannot be restarted until the proper amount of oil has been added. Add the appropriate
type of oil until the oil level is at the proper level. SAE 10W-30 oil is recommended for general use.
NOTICE: Do not run the engine with too little oil.
Engine will shut off if engine oil level is too low.
Economy (ESC) Switch
1. Turn the Economy (ESC) Switch ON to limit noise
and fuel consumption for lighter generator loads.
2. Turn the Economy (ESC) Switch OFF to
operate engine at full speed:
a. when starting
b. when a heavy load is applied
c. when using the 12  V DC output
Digital Display Screen
The Display Screen can be used to monitor the operating
status of the Generator. Use the Display Control Button
to scroll through the following indicators and symbols:
• V – Voltage
• A – Amperage
• VA – Volt Amps  /   W atts
• Hour – current run time and accumulative run time
Page 20
For technical questions, please call 1-888-866-5797.
Plug Load In
Display Screen Symbology
Symbol
Meaning
Normal
U >
AC Overvoltage
U <
AC Undervoltage
I >
Generator Output
Overcurrent
Generator Output
Short Circuit
Inverter
Overheating
ITEM 70143