Advertisement

displays the total weight and the number-of-pieces field the total weight.
H
Meaning the preset quantity is exceeded and an audible warning is given.
5.3The quantity field displays the following information:
F---1
The value of the number-of-pieces exceeds the range of display
5.4 Indicators
kg ( g )
lb
SAMP↑
UNIT↑
Under-voltage
Charging
Fully charged
6 . Setting of adjustable parameters
Start the unit by holding down the "QTY PST" key till it comes to "F----3" and you are in the
setting mode. Press the "QTY PST" key to change the parameters to be set and press the
"TARE" key to change the parameter value.
C1---- for setting the sensitivity at 0 1 2 3 4. The higher the value and the poorer the
sensitivity, the better the stability is. The factory setting is 2.
C2---- for setting the filtering intensity at 0 1 2 3. The higher the value and the slower the
response speed, the better the stability is. The factory setting is 1 or 0.
C3---- for setting the baud rate at 2(600) 3(1200) 4(2400) 5(4800) 6(9600). The factory
setting is 6.
C4---- for setting the communication number. The "TARE" key changes the low-value and
the "kg/lb" key changes the high-value. The data are the first data to be received during the
communication. The factory setting is 27.
Start the unit by pressing the "TARE" key and all set parameters and calibrated data return
the factory state. Before service, perform re-calibration.
Lights when the data are stable. The current weight unit is in kg ( g )
Lights when the data are stable. The current weight unit is in lb.
Lights when the total sampling amount is less than the min. sampling value.
Now, add the number of samples till the indicator is out. Set by re-sampling to
ensure the accuracy.
Lights when the average or set unit weight is less than the min. unit weight
value. Now, the counting weighing apparatus remains serviceable but error may
happen during the counting. It is recommended that counting weighing
apparatus with high distinguishability is used.
Lights when the voltage of the battery is insufficient along with audible alarm,
charge the battery. Otherwise, the battery operates only 1-2 hours. The counting
weighing apparatus operates normally during the charge.
Lights when the counting weighing apparatus is in the charging state. It takes
about 8 hours for one charge.
Slowly lights when the counting weighing apparatus is under charge. When the
charging lamp dies out, it indicates that it is fully charged. Now, it allows further
charging.

Advertisement

loading

This manual is also suitable for:

Tj seriesTj6kTj15kTj30k