4. Illustration of keys
0-9
Keys for entering numbers
.
In the number-entering state, it is a key for decimal. When not in the number-entering state, it is
the printing key.
CE
In the number-entering state, it clears the entered numbers.
When it is not in the number-entering state, press and hold the "CE" key followed by
pressing the "UNIT W.T." key and you are in the calibration mode.
TARE
In the number-entering state, press the "TARE" key, packaging pre-removal is provided for
the current entered value.
When it is not in the number-entering state, pressing the "TARE" key clears the current
weight.
In the calibration state, press the "TARE" key and you are out of the calibration state.
kg/lb
The unit in the weight window between kg(or g) and lb.
UNIT
In the number-entering state, press the "UNIT W.T." key and the current entry is set as unit
W.T.
weight.
SMPL
In the number-entering state, press the "SMPI" key and the current entry is set as number of
pieces.
To set the number of pieces, the displayed data in the weight field must be more than 0.
Otherwise the set number of pieces is 0.
M+
When the displayed data in the weight field is more than 0, accumulated weight value and
value for number of pieces are re-established after the unit weight window displays the
accumulated number of operations for 5s, and the next accumulation is possible only when
the weight returns to 0.
MC
Allowing you to get out of the accumulation state and clear the accumulated value.
QTY
In the number-entering state, press the "QTY PST" key to set the current entry as the upper
PST
limit of the quantity.
When it is not in the number-entering state, the quantity window displays the preset quantity
and returns after 5s.
5. Information displayed on the counting weighing apparatus
5.1The weight field displays
F----1
Data exceeds the range of display.
F----2
Error in A/D conversion circuit
F----3
Indicating that keys are available
F----5
Indicating fault in the sensor
F----L
Zero of sensor signal is too low
F----H
Weight exceeds the range
C----F
Error in calibration. It is not at zero or the data are not stable during the calibration.
C----H
Error in calibration. Article is placed on the weighing platform or the zero of the sensor
is too high during the calibration.
E-----
Error in storing the calibration data. Service is possible only after re-calibration.
5.2 The unit weight field displays the following information:
-CAL-
You are in the calibration state
≡ X≡
The displayed value is the number of operations for accumulation. The weight field

Advertisement