U-Line UHNB115-IS01A User Manual & Service Manual page 53

Table of Contents

Advertisement

USER GUIDE
APPENDIX
E11: Sensor in base near fan detecting water
This sensor is designed to detect water escaping the
product due to any type of malfunction inside the machine.
Once activated, the only way to reset this error is to
completely dry the two probes and cycle power to the
machine via the rocker switch or power cord. Once power
is cycled, it will take 20 minutes to reactivate the error
code. Only the drain pump will retain power and be able to
activate under this condition.
Inspect the entire base area in front and behind
the sensors.
Water
Sensors
Area Behind
Sensors
Area Behind Sensors is Wet
1.
If the unit is equipped with a drainage pump, inspect it
for leaks - check connections.
2.
Remove pump and check all connections on water
valves, water supply, and drain.
3.
Check bolt on water reservoir. If loose, it may leak
during a clean cycle when reservoir is filled to the top.
Torque Spec. is 16 in-lbs.
4.
Check areas around ice maker auger on both ends. If
any leakage is evident, it is likely poor water quality
and/or failure to clean is the cause.
a.
Check TDS (see WATER HOOK UP section) - if
outside tolerance, please report to factory and
advise homeowner that repairs cannot be made
to unit until water quality issue is resolved. Filters
available at u-line.com are able to treat TDS up to
600.*
Troubleshooting Extended
Area In
Front
Sensors
b.
If TDS is acceptable, unit must be cleaned and
any leakage addressed with a seal kit. (U-Line
service part # 80-55371-13)
*SEE "WATER HOOKUP" SECTION FOR SPECIFIC
INFORMATION REGARDING TDS LEVELS
Area in Front of Sensors (Condenser Side) is Wet
Check connection from bin to drain.
No Water is Evident
1.
Power cycle to reset error
2.
Check sensors to ensure there is a gap between
sensors and pan as shown.
3.
If error persists, check wiring to sensors for a
short.
Gap
E12: Float switch in reservoir not rising
This error is designed to ensure sufficient water exists to
produce ice, thus preventing permanent damage to the
module.
In order for this error to occur, the ice-making
sequence must initiate two tries to fill the reservoir. This
may take an hour or more to generate the error code.
Steps to check and correct - remember it is
necessary to power cycle after making the
corrections.
1.
Check incoming water supply to ensure it is turned on
and has sufficient pressure.
2.
Verify water filter (if applicable) is in place and has
been replaced on schedule.
3.
If unit is a 1 Class product, enter service mode and
activate relay 4 to determine if unit fills with water.
a.
If it does not fill, check water valve for power
during sequence.
If there is power, check valve resistance to
determine if coil is shorted.
Check valve to ensure it is not blocked with
debris.
53