AEG IKE95771FB User Manual page 11

Hide thumbs Also See for IKE95771FB:
Table of Contents

Advertisement

Available languages

Available languages

• when the hob is deactivated but the
cooking zone is still hot.
The indicator disappears when the
cooking zone has cooled down.
5.7 Timer
Count Down Timer
Use this function to specify how long a
cooking zone should operate during a
single cooking session.
Set the heat setting for the selected
cooking zone and then set the function.
You cannot activate the
function while the Hob²Hood
function is running.
1. Press
. 00 appears on the timer
display.
2. Press
or
to set the time (00-99
minutes).
3. Press
to start the timer or wait 3
seconds. The timer begins to count
down.
To change the time: select the cooking
zone with
and press
To deactivate the function: select the
cooking zone with
remaining time counts back to 00.
The timer finishes counting down, a
signal sounds and 00 blinks. The cooking
zone deactivates. Press any symbol to
stop the signal and blinking.
Minute Minder
You can use this function when the hob
is activated but the cooking zones do not
operate. The heat setting shows 00.
You cannot activate the
function while the Hob²Hood
function is running.
1. Press
.
2. Press
or
to set the time.
The timer finishes counting down, a
signal sounds and 00 blinks. Press any
symbol to stop the signal and blinking.
or
.
and press
. The
To deactivate the function: press
and
. The remaining time counts back
to 00.
5.8 Power management
If multiple zones are active and the
consumed power exceeds the limitation
of the power supply, this function divides
the available power between all cooking
zones (connected to the same phase).
The hob controls heat settings to protect
the fuses of the house installation.
• If the hob reaches the limit of
maximum available power (refer to
the rating plate), the power of the
cooking zones will be automatically
reduced.
• The heat setting of the cooking zone
selected first is always prioritised. The
remaining power will be divided
between the previously activated
cooking zones according to the order
of selection.
• For cooking zones that have a
reduced power, the control bar blinks
and shows the maximum possible
heat settings.
• Wait until the display stops flashing or
reduce the heat setting of the cooking
zone selected last. The cooking zones
will continue operating with the
reduced heat setting. Change the
heat settings of the cooking zones
manually, if necessary.
5.9 Menu structure
The table shows the basic menu
structure.
User settings
Sym‐
Setting
bol
b
Sound
H
Hood mode
E
Alarm / error
history
To enter user settings: press and hold
for 3 seconds. Then, press and hold
ENGLISH
11
Possible op‐
tions
On / Off (--)
0 - 6
The list of recent
alarms / errors.