With power off, add a jumper, 10047-1677 to power supply J200 between positions 1 and 2.
Attach the LED type to be used with the power supply, installing the correct jumpers to J203 if
required per Figures 7, 8 and 9. Install the LED board to the power supply per Section 10.4. With
all personal safely isolated from your maintenance facility reprogramming set-up, energize the
circuit. The circuit must run for a minimum of 10 seconds, and with the power supply at the high
step of 6.6A during this 10 second minimum for the e-prom to reset and accept its new settings.
The power supply will blink the LED after 10 seconds, indicating it has been reset. Remove the
jumper from power supply J200, positions 1 to 2 after the power supply is safely de-energized
after the 10 second minimum reset period.
10.10

Pressure Test

A light unit should be subjected to a 20-psi maximum air pressure test to verify that it is waterproof
whenever it has been opened or components have been replaced. A tire valve style pressure fitting is
located on the underside of the inner cover. Pressurize the light unit to 20-psi using a regulated/controlled
air source, then place it in a tub of water or use a soap solution to locate escaping air bubbles. Carefully
inspect the areas around the lens, inner cover seal, and feed-thru adapter for leaks. Relieve the internal air
pressure before installing the light unit or attempting to repair a leak.
WARNING
and/or permanent damage to the light unit may result if a higher air pressure
Instruction Manual
PRO APF Series LED
Inset Runway Guard Light L-852G
Do not exceed 20-psi when pressure testing the light unit. Serious injury
is used. Once the pressure test is complete, be sure to relieve the air
WARNING:
pressure.