Installation Details; Wrench Torque Sheet For Installation; Connecting The Cables; Pipe Length And The Elevation - Fisher FSI-95HFD Service Manual

Table of Contents

Advertisement

8.

Installation details

8.1

Wrench torque sheet for installation

8.2

Connecting the cables

The power cord of connect should be selected according to the following specifications sheet.
8.3

Pipe length and the elevation

Pipe size
Capacity
Btu/h
GAS
FSI-09HFD
3/8'' (φ9.52)
FSI-125HFD 1/2'' (φ12.7)
Caution:
Capacity is base on standard length and maximum allowance length is base of reliability.
12
Service manual
Outside diameter
mm
inch
1/4
φ6.35
3/8
φ9.52
1/2
φ12.7
5/8
φ15.88
3/4
φ19.05
Unit
2
mm
LIQUID
1/4'' (φ6.35)
1/4'' (φ6.35)
Torque
Kg.m
1.8
4.2
5.5
6.6
6.6
Grade
9K
12K
1.5
1.5
Standard
Max.
length
Elevation
(m)
B (m)
5
5
5
5
Max.
Additional
Length
refrigerant
A (m)
(g/m)
10
30
10
30