Page 4
PRODUCT MANUAL Lynx™ Quad Temperature Modules LS‑QTTB‑J & LS‑QTTB‑K TROUBLESHOOTING MEASUREMENT ERRORS CONNECTION PROBLEMS WIRE EXTENSIONS NOISE INSTALLATION ERRORS REVERSED CONNECTIONS LOOSE CONNECTIONS CUSTOMER SUPPORT RELATED PRODUCTS COMPATIBLE PRODUCTS SPRING‑LOADED 1.5 MM TEMPERATURE SENSOR TS‑SL01.5‑K PRESS‑FIT 3 MM CAVITY TEMPERATURE SENSOR TS‑PF03‑K 1 MM FLUSH MOUNT CAVITY TEMPERATURE SENSOR TS‑FM01‑K Lynx™...
Page 5
This guide must be kept available for reference at all times. DISCLAIMER PRIVACY Inasmuch as RJG, Inc. has no control Designed and developed by RJG, Inc. over the use to which others may put Manual design, format and structure this material, it does not guarantee that copyright 2022 RJG, Inc.
PRODUCT DESCRIPTION The Lynx™ Quad Temperature Modules LS‑QTTB‑J and LS‑QTTB‑K accept input from up to four thermocouples (type J or type K) for use with the RJG, Inc. eDART® or CoPilot® systems. APPLICATIONS A calibration factor is used to compute...
LS‑QTTB‑K is compatible with locations include nozzle, front, center, feed throat, and rear. type K thermocouples; RJG, Inc. offers a line of type K thermocouples. The 3. Dryer Temperature Monitoring LS‑QTTB‑J/K modules feature terminal A sensor or sensors can be placed in the block connectors and accepts input from a dryer and connected to the LS‑QTTB‑J/K...
INSTALLATION INSTALLATION OVERVIEW The LS‑QTTB‑J/K is grounded and mounted over the area where the thermocouple wires exit the mold, but away from extensive heat or vibration/shock. The thermocouple wires are inserted into the module and installed using the terminal block. A Lynx cable is attached to the LS‑QTTB‑J/K Lynx port and the eDART or CoPilot system.
INSTALLATION SPECIFICATIONS (continued) MOUNTING 3. Remove cover. 1. Requirements • Remove screws ( ) from LS‑QTTB‑K, then The Lynx quad temperature module must remove cover plate. be mounted on a frame‑grounded structure to ensure proper operation. The ground 4. Insert thermocouple wire. potential of the structure must be same as the ground required for the eDART or Feed thermocouple wire (...
INSTALLATION SPECIFICATIONS (continued) CONNECTIONS 1. Requirements 3. Connect negative (‑) lead. The thermocouple wires must be shielded, • Connect white wire ( ) to the negative however, wires that remain within the mold terminal. may not be shielded. The shielded wires 4.
The LS‑QTTB‑J/K requires eDART software previously been configured, all four version 8.0 or eDART software version channels will be assigned as “Mold 10.xx or later; contact RJG Customer temperature” with no Sensor Location Support if a software upgrade is required. assigned.
Page 14
INSTALLATION SPECIFICATIONS (continued) 3. Software Setup Version 10.xx The LS‑QTTB‑J/K and associated sensor list into the Other Sensors machine may be set up during the Machine Setup/ location listed on the left to designate Inputs or Mold Setup/Inputs in the the sensor type;...
Page 15
INSTALLATION SPECIFICATIONS (continued) MOLD INPUT SETUP • Click, drag, and drop the associated • For mold sensors , runner, surface, sensor from the Available Sensors parting line, sprue, or coolant list into the Mold Sensors machine temperature can be selected; for cavity location or the desired cavity listed on types...
MAINTENANCE PRODUCT DISCLAIMER CLEANING Keep sensor pocket, cable channel, and RJG, Inc. is not responsible for the sensor components free from oil, dirt, improper installation of this equipment, or grime, and grease. any other equipment RJG manufactures. TESTING & CALIBRATION...
TROUBLESHOOTING MEASUREMENT ERRORS Errors in measurement can result from connection problems, lead resistance issues, or electrical noise. CONNECTION PROBLEMS Connections must be clean and free from oil, dirt, grime, and grease. If shielded wire is used, the wire must run under the LS‑QTTB‑J/K shield plate ( & ...
INSTALLATION ERRORS REVERSED CONNECTIONS Connections must not be reversed ( & at right . Reversed leads will provide a reading which will vary in the opposite direction relative to ambient temperature. LOOSE CONNECTIONS Ensure connections are firmly in place, but are no over‑tightened.
CUSTOMER SUPPORT Contact RJG’s Customer Support team by phone or email. RJG, Inc. Customer Support P: 800.472.0566 (Toll Free) P: +1.231.933.8170 www.rjginc.com/support Product Manual | Lynx™ Quad Temperature Modules LS‑QTTB‑J & LS‑QTTB‑K...
RELATED PRODUCTS COMPATIBLE PRODUCTS The LS‑QTTB‑J/K temperature sensor is compatible with other RJG, Inc. products for use with the eDART or CoPilot process control and monitoring systems. The LS‑QTTB‑K is compatible with the following RJG, Inc. temperature sensors. SPRING‑LOADED 1.5 MM TEMPERATURE SENSOR TS‑SL01.5‑K...