Advertisement

All manuals and user guides at all-guidesbox.com
PM54
Installation Manual
Australia
RDCCO Pty Ltd
Unit 3/9 – 11 South Street
Rydalmere NSW 2116
+61 2 9352 1777
Email: support@permaconn.com
Web: www.permaconn.com

Advertisement

Table of Contents
loading

Summary of Contents for Permaconn PM35

  • Page 1 All manuals and user guides at all-guidesbox.com PM54 Installation Manual Australia RDCCO Pty Ltd Unit 3/9 – 11 South Street Rydalmere NSW 2116 +61 2 9352 1777 Email: support@permaconn.com Web: www.permaconn.com...
  • Page 2: Table Of Contents

    PM54 Alarm Panel Connection / Resetting the PM54 / Activating the PM54.....8 PM54 - LED Status Indicators ....................9 Serial Interface........................10 Upload / Download......................11 IP Setup........................12-17 Device Use Cases......................18-19 Transmission Delay Times ....................20 Permaconn Contact ID Event Template..............20-21 PM54 Specifications......................22 Warning / Liability......................23 PM54 Installation Manual v1 RDCCO_2195_E_IN...
  • Page 3: Introduction / Features

    The Permaconn system provides two-way communication between supervised premises and the Monitoring Centre. The Permaconn PM54 is a market leading next-generation connectivity solution for any network- ready device or computer system. The PM54 is a 3 in 1 device that combines an alarm communi- cator with a high-speed 4G router (gateway) and a Wi-Fi hotspot.
  • Page 4: Atlas Web Platform / Poll Plans / Data Plans

    Atlas Web Platform Atlas is a secure web portal that enables users to activate, interrogate and configure Permaconn communicators and routers remotely for diagnostic and control purposes. This portal can be accessed via the web using any Smartphone, Tablet or PC.
  • Page 5: Installation Procedure Pm54

    Option 2: Use a 4 core cable between PM45 and alarm panel dialler terminals. Connection diagrams available: https://www.permaconn.com/installer-zone/technical-addendums  ‗Ring‘ & ‗Tip‘ as the input and ‗R1‘ & ‗T1‘ as the return line. If the return line is not connected the ‗CID‘...
  • Page 6: Programming The Alarm Panel / Antenna Installation

    The PM54 is supplied with three antennas  If signal strength is low, a high gain antenna may be required. This can be purchased separately from Permaconn or one of our distributors  Extension cables for the high gain aerial are available...
  • Page 7: Device Outputs / Device Inputs

    The outputs can only be pulsed when using the Pocket Secure App.  Refer to the technical addendums for detailed key switch information. www.permaconn.com / Installer Zone / Technical Addendums Compatible with ‗Pocket Secure‘ remote control App. Available on the Apple, Google Play and Windows store Device Inputs ...
  • Page 8: Pm54 Alarm Panel Connection / Resetting The Pm54 / Activating The Pm54

    Procedure to activate the PM54  Login to Atlas  Select the ‗Fleet‘ tab  Click the ‗Activate‘ button  Input Permaconn‘s serial number (starting with #)  Fill in the form and follow the prompts PM54 Installation Manual v1 RDCCO_2195_E_IN...
  • Page 9: Pm54 - Led Status Indicators

    All manuals and user guides at all-guidesbox.com PM54 - LED Status Indicators PM54 - LED Status Indicators Activity Indication Signal strength OK / Processor OK Green Flashing Signal strength low or trying to Red Flashing reconnect Flash Red Data traffic on 3G/4G Only 1 sim working Mobile Green Flashing...
  • Page 10: Serial Interface

    All manuals and user guides at all-guidesbox.com Serial Interface Compatible Set as in Atlas The alarm panel must be programmed Panels with:  Serial Data (contact ID format) Tecom  Account ID Concept MCM icon Siemens Cardax Cardax NB: This is set during activation process PM54 ...
  • Page 11: Upload / Download

    All manuals and user guides at all-guidesbox.com Upload / Download (Using Permaconn 4G or IP) Panel Client Software (PCS) is a virtual modem application that enables remote access to the alarm panels using wireless 4G or Ethernet connec- PM54 tion.
  • Page 12: Ip Setup

    All manuals and user guides at all-guidesbox.com IP Setup Before you start you need the following:  Access to the Atlas portal  Connect the PM54 to the on-site internet gateway with a standard CAT5/6 patch lead.  The PM54 must be online (via IP or 4G) and accessible in Atlas to make changes. To utilize an on-site internet connection: ...
  • Page 13 All manuals and user guides at all-guidesbox.com IP Setup cont..This is View only Configure the WAN interface to connect to an on-site Internet Gateway WAN disabled (Reset) Utilising the customers‘ internet: 1: Connect a Cat5 / 6 cable between the WAN port on the PM54 to the customers‘ internet router 2: Tick the Enable WAN connection press save.
  • Page 14 All manuals and user guides at all-guidesbox.com IP Setup cont..Configure the WAN interface to connect to an on-site Internet Gateway Additional WAN settings Option 1: Ethernet Cable - Connect a RJ45 Patch lead between the WAN on the PM54 and a port on the customers router. Option 2: WiFi STA - This will allow WiFi connection from the PM54 to the customers WiFi STA...
  • Page 15 All manuals and user guides at all-guidesbox.com IP Setup cont..Configure the LAN interface to set a Reset gateway for connected devices and optionally enable the DHCP server to assign IP‘s to connected devices DHCP Range setting Example shown: Limit 100—150 Is IP 192.168.111.100—192.168.111.150.
  • Page 16 Allow inbound connections to devices that are connected to the PM54 LAN port from the internet Using the standard Data Plan the IP Address Enabled field is hidden. To use the Port forward option, please call Permaconn to obtain a Data Plan containing a Public IP address, there are a limited number available. Enabled 123.123.123.123 Port Forwarding must be done in Atlas, Once the IP Address can be viewed select the ‗add‘...
  • Page 17 All manuals and user guides at all-guidesbox.com IP Setup cont..Port Forwarding example: Using the PM54 as an Internet Router E.g IP 111.111.111.111 Port 8080 E.g IP 192.168.0.222 Port 80 DVR or NVR 8080 192.168.0.222 PM54 Installation Manual v1 RDCCO_2195_E_IN...
  • Page 18: Device Use Cases

    All manuals and user guides at all-guidesbox.com Device Use Case Standalone Alarm Communicator providing an Internet Gateway This configuration will deliver alarm events to the control room, allow remote UDL of the alarm panel, allow remote management of the Input / Output via Pocket Secure and provide an internet connection to both wireless and Wi-Fi devices connected to the PM54 device.
  • Page 19 All manuals and user guides at all-guidesbox.com Device Use Case cont..Alarm Communicator providing a fallback Internet Gateway This configuration will deliver alarm events to the control room, allow remote UDL of the alarm panel, allow remote management of the Input / Output via Pocket Secure and provide an internet connection to devices connected to the PM54 device;...
  • Page 20: Transmission Delay Times

    Auxiliary 2 — Auxiliary input alarm on communicator. Auxiliary 3 — Auxiliary input alarm on communicator. Panel ID Clash— When two (2) Permaconn devices are reporting to the same Control Room on the same line number using the same account number.
  • Page 21 All manuals and user guides at all-guidesbox.com Permaconn Contact ID Event Template cont…. Special Events generated by the new Permaconn 54 Communicator Event ID Partition Zone Description Data Usage has reached 80% of allowance Data Usage has reached 95% of allowance...
  • Page 22: Pm54 Specifications

    All manuals and user guides at all-guidesbox.com PM54 Specifications 4G LTE-FDD Frequency: B1(2100) B3(1800) B5(850) B8(900) B28(700) Bandwidth: Max 10Mbps (DL) Max 5Mbps (UL) 3G HSPA+ Frequency: B1(2100) B5(850) B8(900) Bandwidth: Max 42Mbps (DL) Max 5.76Mbps (UL) Antennas 2 antennas for Cellular (MIMO) + 1 for Wi-Fi WIFI Capability Supports: IEEE 802.11b/g/n Frequency: 2.4GHz...
  • Page 23: Warning / Liability

    Standards require regular service by qualified and licensed technicians and regular testing. Liability ANY LIABILITY FOR CONSEQUENTIAL AND INCIDENTAL DAMAGES IS EXPRESSLY DIS- CLAIMED. RDCCO Pty Ltd AND PERMACONN LIABILITY IN ALL EVENTS IS LIMITED TO, AND SHALL NOT EXCEED, THE PURCHASE PRICE PAID. PM54 Installation Manual v1...

This manual is also suitable for:

Pm54

Table of Contents