Press and hold "M", within 6 seconds, short press " > "
to lock keyboard, icon "
repeat this to unlock.
7. Reset
During power off, press and hold both "M" and" < ",
" > " for 10 seconds, thermostat will be reset and
restart.
8. Auto switch between heating and cooling
When auto switch between heating and cooling On,
heating and cooling is automatically controlled by
the parameters P16,P17 and P19. The temperature
is controlled by the set temperature and the dead
zone is decided via the parameters P16 for Normal
mode and P17 for ECO mode.
9. Floor/radiator for heating & fan coil for cool-
ing
If P18 is Off
The fan is controlled by the Fan Speed Selection
If P18 is On
The fan is disabled, when heating is on. When
cooling,the fan is controlled by the Fan Speed
Selection
8. Programming
1. 5-2 day programming
To enable this function, please configure P01 to "02"
in parameter setting.
When this function is enabled, system automatically
changes setting temperature four times per day.
Danfoss Heating Solutions
GreenCon RC-C2/C4
" will be displayed on LCD,
VIE2C32P
GB
9