Drainage (Dp); Air Intake; Vented System; Equipotential Bonding - Miele PDW 909 SOM Installations Plan

Washer-dryer stack
Hide thumbs Also See for PDW 909 SOM:
Table of Contents

Advertisement

Available languages

Available languages

Drainage (DP)

Maximum waste water temperature
Drain connection (on machine)
Maximum drainage rate

Air intake

Recommended free air intake cross-section into the room:
(equivalent to 3 times the exhaust air cross-section of an appliance).
There must be sufficient air intake to the installation site to match the air outlet volume.

Vented system

Maximum nominal volume flow rate
Maximum permitted pressure loss
Connector on machine side (external diameter)
Connection pipe provided on site (internal diameter)
Maximum exhaust air temperature
As relative humidity inside the exhaust ducting can be as high as 100 %, suitable measures must be taken to prevent a backflow of
condensate into the appliance.

Equipotential bonding

If local and national installation specifications require equipotential bonding, good galvanic contact must be guaranteed. Accessories
for equipotential bonding are not supplied and need to be ordered separately.

Installation dimensions

Casing width (without add-on components)
Casing height (without add-on components)
Casing depth (without add-on components)
Overall machine width
Overall machine height
Overall machine depth
Minimum width of transport opening
Minimum safety distance between wall and back of machine
Diameter of door opening
Door opening angle
Standard
Required anchor points
DIN 571 wood screw (diameter x length)
Rawl plugs (diameter x length)
en - Technical data
External diameter 22 (DN 22)
12 mm x 90 mm
16 mm x 80 mm
95 °C
26 l/min
237 cm²
320 m³/h
220 Pa
100 mm
100 mm
80 °C
692 mm
1940 mm
761 mm
692 mm
1942 mm
851 mm
800 mm
400 mm
370 mm
180°
4
51