Technical White Paper About This Document About This Document Purpose This document describes the FusionServer 5288 V5 rack server in terms of features, structure, specifications, and component hardware and software compatibility. Intended Audience This document is intended for pre-sales engineers.
Page 4
FusionServer 5288 V5 Server Technical White Paper About This Document Change History Issue Date Description 2023-04-30 Updated 6.1 Technical Specifications. 2022-11-30 Updated A.4 Nameplate . 2022-11-11 ⚫ Updated 6.3 Physical Specifications . Updated 8.1 Security. ⚫ 2022-08-12 Optimized 6.3 Physical Specifications .
1 Product Introduction Product Introduction FusionServer 5288 V5 (5288 V5) is a new-generation 4U dual-socket or single-socket storage server designed for media and entertainment, and finance fields. The 5288 V5 is ideal for applications such as cold data storage, video surveillance, cloud storage, and big data processing.
FusionServer 5288 V5 Server Technical White Paper 2 Features Features Performance and Scalability ® ® ⚫ Powered by two Intel Xeon Scalable Skylake or Cascade Lake processors, the server provides up to 28 cores, 3.8 GHz frequency, a 38.5 MB L3 cache, and two 10.4 GT/s UPI links between the processors, which deliver supreme processing...
Page 9
FusionServer 5288 V5 Server Technical White Paper 2 Features ⚫ The use of all solid-state drives (SSDs) is supported. An SSD supports up to 100 times more I/O operations per second (IOPS) than a typical hard disk drive (HDD). The use of all SSDs provides higher I/O performance than the use of all HDDs or a combination of HDDs and SSDs.
Page 10
FusionServer 5288 V5 Server Technical White Paper 2 Features The BIOS firmware digital signature update mechanism is supported. During − the upgrade, the digital signature is verified to prevent unauthorized BIOS firmware upgrade. The flash security protection mechanism is supported to prevent −...
FusionServer 5288 V5 Server Technical White Paper 3 Physical Structure Physical Structure Figure 3-1 5288 V5 physical structure I/O module 1 I/O module 2 Rear drive Rear-drive backplane I/O module 3 Chassis Power supply unit (PSU) (Optional) built-in drive module...
Page 12
FusionServer 5288 V5 Server Technical White Paper 3 Physical Structure Front drive backplane Front drive Fan module bracket Fan module Heat sink Processor Memory Mainboard Cable organizer TPM/TCM RAID controller card (Optional) FlexIO card a: Install either the air duct or built-in drive module.
FusionServer 5288 V5 Server Technical White Paper 4 Logical Structure Logical Structure Figure 4-1 5288 V5 logical structure ® ® ⚫ The server supports one or two Intel Xeon Scalable processors. ⚫ The server supports up to 24 memory modules.
Page 14
FusionServer 5288 V5 Server Technical White Paper 4 Logical Structure ⚫ Uses the BMC management chip, and supports a VGA, a management network port, a debugging serial port, and other management ports. ⚫ The BMC management chip can be an enhanced management chip (VB) or an ordinary management chip.
FusionServer 5288 V5 Server Technical White Paper 5 Hardware Description 5.1 Front Panel 5.1.1 Appearance Figure 5-1 Front view Left mounting ear Drives Slide-out label plate (with Right mounting ear an SN label) 5.1.2 Indicators and Buttons Indicator and Button Positions...
Page 17
FusionServer 5288 V5 Server Technical White Paper 5 Hardware Description status indicator status indicator Fault diagnosis LED Health status indicator UID button/indicator Power button/indicator Indicator and Button Descriptions Table 5-1 Description of indicators and buttons on the front panel Sign...
Page 18
FusionServer 5288 V5 Server Technical White Paper 5 Hardware Description Indicator and Sign Description Button ⚫ You can control the UID indicator status by pressing the UID button or using the iBMC. ⚫ You can press this button to turn on or off the UID indicator.
FusionServer 5288 V5 Server Technical White Paper 5 Hardware Description 5.1.3 Ports Port Positions Figure 5-3 Ports on the front panel USB 2.0 ports Port Description Table 5-2 Ports on the front panel Port Type Quantity Description USB port USB 2.0 Used to connect to a USB device.
FusionServer 5288 V5 Server Technical White Paper 5 Hardware Description 5.2.2 Indicators Indicator Positions Figure 5-5 Indicators on the rear panel LOM port indicator LOM port indicator Data transmission status Connection status indicator indicator of the of the management management network port...
FusionServer 5288 V5 Server Technical White Paper 5 Hardware Description Indicator Description Power output overcurrent or short-circuit ⚫ ⚫ Output overvoltage Short-circuit protection ⚫ ⚫ Device failure (excluding failure of all devices) UID Indicator The UID indicator helps identify and locate a device.
Page 23
FusionServer 5288 V5 Server Technical White Paper 5 Hardware Description Port Description Table 5-4 Description of ports on the rear panel Tool Type Quantity Description LOM port 1 10GE SFP+ or 10GE LOM service ports 10GE BASE-T (optical/electrical). Use the optical or electrical ports based on service requirements.
FusionServer 5288 V5 Server Technical White Paper 5 Hardware Description Tool Type Quantity Description power of the PSUs is greater than that of the server. If only one PSU is used, ⚫ Predicted PSU Status cannot be set to Active/Standby on the iBMC WebUI.
FusionServer 5288 V5 Server Technical White Paper 5 Hardware Description 5.4 Memory 5.4.1 DDR4 Memory 5.4.1.1 Memory Identifier You can determine the memory module properties based on the label attached to the memory module. Figure 5-8 Memory identifier Callout Description...
FusionServer 5288 V5 Server Technical White Paper 5 Hardware Description Memory Channel Memory Slot DIMM131(J) E (primary) DIMM140(E) DIMM141(K) F (primary) DIMM150(F) DIMM151(L) 5.4.1.3 Memory Compatibility Observe the following rules when configuring DDR4 DIMMs: ⚫ A server must use the same model of DDR4 DIMMs, and all the DIMMs operate at the same speed, which is the smallest value of: ⚫...
Page 28
FusionServer 5288 V5 Server Technical White Paper 5 Hardware Description ⚫ The total memory capacity cannot exceed the maximum memory capacity supported by the CPUs. ⚫ The total memory capacity refers to the capacity when DDR4 DIMMs are fully configured. For details about the memory capacity when DCPMMs are used together with DDR4 DIMMs, see 5.4.2.3 Memory Compatibility.
FusionServer 5288 V5 Server Technical White Paper 5 Hardware Description 5.4.1.4 DIMM Installation Rules This section applies to a server fully configured with DDR4 DIMMs. If DCPMMs are used together, see 5.4.2.4 DIMM Installation Rules. ⚫ Observe the following when configuring DDR4 memory modules: Install memory modules only when corresponding processors are installed.
FusionServer 5288 V5 Server Technical White Paper 5 Hardware Description Figure 5-11 DDR4 memory installation guidelines (2 processors) 5.4.1.6 Memory Protection Technologies The following memory protection technologies are supported: ⚫ ⚫ Full mirroring ⚫ Address range mirroring ⚫ SDDC ⚫...
FusionServer 5288 V5 Server Technical White Paper 5 Hardware Description Table 5-7 Memory channels Memory Channel Memory Slot CPU 1 A (primary) DIMM000(A) DIMM001(G) B (primary) DIMM010(B) DIMM011(H) C (primary) DIMM020(C) DIMM021(I) D (primary) DIMM030(D) DIMM031(J) E (primary) DIMM040(E) DIMM041(K)
Page 34
FusionServer 5288 V5 Server Technical White Paper 5 Hardware Description ⚫ The DCPMMs must be used with the DDR4 memory modules. For details, see the FusionServer DCPMM User Guide. ⚫ Contact your local sales representative or use the Compatibility Checker determine the components to be used.
FusionServer 5288 V5 Server Technical White Paper 5 Hardware Description Item Specifications a: The maximum number of DCPMMs is based on dual-processor configuration. ⚫ The value is halved for a server with only one processor. b: The maximum memory capacity varies depending on the CPU type and ⚫...
FusionServer 5288 V5 Server Technical White Paper 5 Hardware Description Figure 5-15 DCPMM and DDR4 memory configuration guidelines (2 processors) Figure 5-16 DCPMM and DDR4 memory configuration guidelines 5.4.2.6 Memory Protection Technologies The following memory protection technologies are supported: ⚫...
FusionServer 5288 V5 Server Technical White Paper 5 Hardware Description ⚫ DCPMM DDR-T fault tolerance ⚫ Faulty DCPMM isolation 5.5 Storage 5.5.1 Drive Configurations Table 5-10 Drive configuration Configuratio Maximum Maximum Maximum Common Number of Number of Number of Drive...
Page 39
FusionServer 5288 V5 Server Technical White Paper 5 Hardware Description Configuratio Maximum Maximum Maximum Common Number of Number of Number of Drive Front Drives Rear Drives Built-in Management (pcs) (pcs) Drives (pcs) Mode only SAS or SATA drives. − Slots 32...
Page 40
FusionServer 5288 V5 Server Technical White Paper 5 Hardware Description Configuratio Maximum Maximum Maximum Common Number of Number of Number of Drive Front Drives Rear Drives Built-in Management (pcs) (pcs) Drives (pcs) Mode Dual RAID ⚫ Front drive ⚫ I/O module...
FusionServer 5288 V5 Server Technical White Paper 5 Hardware Description Configuratio Maximum Maximum Maximum Common Number of Number of Number of Drive Front Drives Rear Drives Built-in Management (pcs) (pcs) Drives (pcs) Mode drives ⚫ a: When the rear drives (slot 32 to slot 35) are configured with NVMe drives, the location of IO module 1 needs to be fixed with an NVMe adapter card and cannot be configured with hard drives.
FusionServer 5288 V5 Server Technical White Paper 5 Hardware Description Figure 5-18 Drive numbering 5.5.3 Drive Indicators SAS/SATA Drive Indicators Figure 5-19 SAS/SATA drive indicators Table 5-11 Description of SAS/SATA drive indicators Activity Indicator Fault Indicator Description (Green) (Yellow) The drive is not in position.
Page 44
FusionServer 5288 V5 Server Technical White Paper 5 Hardware Description Activity Indicator Fault Indicator Description (Green) (Yellow) Blinking at 4 Hz Data is being read or written normally, or data on the primary drive is being rebuilt. Steady on Blinking at 1 Hz The drive is being located.
FusionServer 5288 V5 Server Technical White Paper 5 Hardware Description Table 5-13 NVMe drive indicators (VMD disabled) Activity Indicator Fault Indicator Description (Green) (Yellow) The NVMe drive cannot be detected. Steady on The NVMe drive is working properly. Blinking at 2 Hz Data is being read from or written to the NVMe drive.
FusionServer 5288 V5 Server Technical White Paper 5 Hardware Description ⚫ Contact your local sales representative or use the Compatibility Checker determine the components to be used. ⚫ For details about the RAID controller card, see V5 Server RAID Controller Card User Guide.
Page 47
FusionServer 5288 V5 Server Technical White Paper 5 Hardware Description Chip Number Rate Supported Rates Not Port Type Type Model of Ports Negoti Rates Supported ation Mode The LOM ports do not support forced rates. ⚫ ⚫ The electrical LOM ports cannot be connected to power over Ethernet (PoE) devices (such as a switch with PoE enabled).
Page 48
FusionServer 5288 V5 Server Technical White Paper 5 Hardware Description Indicator Positions Figure 5-23 LOM indicators Connection status Data transmission rate indicator/Data transmission indicator for a 10GE optical status indicator for a 10GE port optical port Data transmission rate Connection status...
FusionServer 5288 V5 Server Technical White Paper 5 Hardware Description Indicator Description Data transmission rate Off: The network port is not connected. ⚫ indicator for a 10GE ⚫ Steady green: The data transmission rate of the link is electrical port 10 Gbit/s.
Page 50
FusionServer 5288 V5 Server Technical White Paper 5 Hardware Description Number of Support NIC Model Chip Model Port Type Ports NC-SI/WOL/P √ SM330 X710 10GE optical port √ SM380 25GE optical port Indicator Positions ⚫ SM210/SM212 with four GE electrical ports Figure 5-24 SM210/SM212 network port indicators ⚫...
Page 51
FusionServer 5288 V5 Server Technical White Paper 5 Hardware Description Figure 5-27 SM252 network port indicators ⚫ SM251 with two 56G IB optical ports Figure 5-28 SM251 network port indicators ⚫ SM330 with two 10GE optical port/SM380 with two 25GE optical ports...
Page 52
FusionServer 5288 V5 Server Technical White Paper 5 Hardware Description Port Type Indicator Status status indicator transmitted. ⚫ Steady green: The network port is properly connected. 10GE optical port Transmission rate ⚫ Off: The network port is not indicator connected or the data transmission rate is 100 Mbit/s.
FusionServer 5288 V5 Server Technical White Paper 5 Hardware Description 5.7 I/O Expansion 5.7.1 PCIe Cards PCIe cards provide ease of expandability and connection. ⚫ The electrical ports provided by PCIe NICs cannot be connected to power over Ethernet (PoE) devices (such as a switch with PoE enabled). Connecting such an electrical port to a PoE device may cause link communication failure or even damage the NIC.
Page 54
FusionServer 5288 V5 Server Technical White Paper 5 Hardware Description If six P4 GPU cards are configured: ⚫ ⚫ The GPU cards fit into slots 1 to 6. The processor power must be lower than 130 W. ⚫ ⚫ The GPU cards support the highest temperature of 30° C in stack installation and 35° C in non-stack installation.
Page 55
FusionServer 5288 V5 Server Technical White Paper 5 Hardware Description Figure 5-32 PCIe riser module 2 ⚫ PCIe riser module 3 (for PCIe SSD cards only) − Provides PCIe slots 1, 2, and 3 when installed in I/O module 1.
Page 56
FusionServer 5288 V5 Server Technical White Paper 5 Hardware Description Figure 5-33 PCIe riser module 3 ⚫ PCIe riser module 4 (for P4 GPU cards only) Provides PCIe slots 1, 2, and 3 when installed in I/O module 1. −...
Page 57
FusionServer 5288 V5 Server Technical White Paper 5 Hardware Description Figure 5-34 PCIe riser module 4 ⚫ PCIe riser module 5 Provides PCIe slots 7 and 8 when installed in I/O module 3. Figure 5-35 PCIe riser module 5 Issue 07 (2023-04-30)
Page 58
FusionServer 5288 V5 Server Technical White Paper 5 Hardware Description ⚫ PCIe riser module 6 Provides PCIe slot 7 when installed in I/O module 3. Figure 5-36 PCIe riser module 6 ⚫ PCIe riser module 7 Provides PCIe slot 3 when installed in I/O module 1.
FusionServer 5288 V5 Server Technical White Paper 5 Hardware Description Figure 5-37 PCIe riser module 7 5.7.3 PCIe Slot Description The PCIe slots mapping to a vacant CPU socket are unavailable. Table 5-19 PCIe slot description PCIe PCIe Conne Port...
Page 60
FusionServer 5288 V5 Server Technical White Paper 5 Hardware Description PCIe PCIe Conne Port Root Devic Slot Slot Stand ctor Width Port Size ards Width (B/D/F (B/D/F ⚫ 3-sl Slot 2 CPU 1 PCIe 2-sl Port2C 3A/02/ 3D/00/ 2-sl ⚫...
FusionServer 5288 V5 Server Technical White Paper 5 Hardware Description ⚫ The same model of PSUs must be used in a server. ⚫ The PSUs are protected against short circuit. Double-pole fuse is provided for the PSUs with dual input live wires.
FusionServer 5288 V5 Server Technical White Paper 5 Hardware Description Figure 5-39 Fan module positions 5.10 Boards 5.10.1 Mainboard ⚫ BOM code for mainboards of enhanced management chip (VB): 0302021706, 0302Y076. BOM code for mainboards of normal management chip: 03024AFQ, 03026NEA, 06410432, ⚫...
Page 64
FusionServer 5288 V5 Server Technical White Paper 5 Hardware Description Figure 5-40 5288 V5 mainboard (BOM: 03024AFQ, 03026NEA, 03024CXS, 03029JRP, 0302021706, 0302Y076, 06410432, 06410436, 06410592) USB 3.0 port (USB 3.0 UID indicator (D6020) CONN/J169) Serial port Management network port GE electrical port...
Page 65
FusionServer 5288 V5 Server Technical White Paper 5 Hardware Description PCIe riser 1 slot Rear drive backplane (corresponding to CPU power connector 2 (REAR 1/J108) BP PWR2/J126) NC-SI connector (NCSI SATA signal connector 2 CONN/J99) (SATA2/J71) SATA signal connector 1...
FusionServer 5288 V5 Server Technical White Paper 5 Hardware Description Screw-in RAID controller PCIe riser 2 slot card connector (RAID (corresponding to CARD/J48) CPU2/J155) a: "10GE optical port" corresponds to the mainboard (BOM: 03024AFQ and ⚫ 03026NEA) integrated with two 10GE optical ports and two GE electrical ports.
Page 67
FusionServer 5288 V5 Server Technical White Paper 5 Hardware Description Mini-SAS connector (PORT Mini-SAS connector (PORT C/J65) B/J64) Mini-SAS connector (PORT Signal connector A/J63) (HDDBP/J36) Power connector 2 (POWER2/J69) Built-in-Drive Backplane ⚫ Built-in-Drive Backplane (4xSAS/SATA/NVMe) Figure 5-42 Built-in-drive backplane (4xSAS/SATA/NVMe)(BOM: 03024MBJ)
Page 68
FusionServer 5288 V5 Server Technical White Paper 5 Hardware Description Power connector (J1) ⚫ 4 x 2.5" drive backplane Figure 5-44 4 x 2.5" drive backplane (BOM: 03024BPV and 03029TDR) Power connector (REAR Mini-SAS HD connector BP POWR3/J22) (Port A/J2)
Page 69
FusionServer 5288 V5 Server Technical White Paper 5 Hardware Description (PORT 0/J3) (HDDBP/J1) Mini-SAS connector (PORT Signal connector (REAR A/J28) BP1/J31) Power connector (HDDBP/J24) PCIe signal cables are connected to Mini-SAS HD connectors 3, 4, 5, and 7. ⚫ ⚫...
FusionServer 5288 V5 Server Technical White Paper 6 Product Specifications Product Specifications 6.1 Technical Specifications 6.2 Environmental Specifications 6.3 Physical Specifications 6.1 Technical Specifications Table 6-1 Technical Specifications Component Specifications Form factor 4U rack server ® Chipset Intel C622 Processor Supports one or two processors.
Page 71
FusionServer 5288 V5 Server Technical White Paper 6 Product Specifications Component Specifications RDIMM and LRDIMM support − The DDR4 memory modules of different types − (RDIMM and LRDIMM) and specifications (capacity, bit width, rank, and height) cannot be used together.
Page 72
FusionServer 5288 V5 Server Technical White Paper 6 Product Specifications Component Specifications Supports hot swap of SAS/SATA/NVMe U.2 drives. ⚫ NOTE The NVMe drives support: ⚫ Surprise hot swap if the VMD function is enabled and the latest Intel VMD driver is installed.
Page 73
FusionServer 5288 V5 Server Technical White Paper 6 Product Specifications Component Specifications disconnection and disable the WOL function of the LOM ports. To restore the NC-SI connection, refresh the iBMC WebUI. I/O expansion 10 PCIe 3.0 slots: One slot dedicated for a screw-in RAID controller card, ⚫...
FusionServer 5288 V5 Server Technical White Paper 6 Product Specifications Component Specifications operating system is provided. System management ⚫ Supports UEFI. Supports iBMC. ⚫ ⚫ Supports NC-SI. Supports integration with third-party management ⚫ systems. Security feature ⚫ Power-on password Administrator password ⚫...
Page 75
FusionServer 5288 V5 Server Technical White Paper 6 Product Specifications Category Specifications Classes A1 and A2 and the altitude is above 900 m (2952.76 ft), the highest operating temperature decreases by 1° C (1.8° F) for every increase of 300 m (984.25 ft).
FusionServer 5288 V5 Server Technical White Paper 6 Product Specifications Maximum preservation duration of HDDs: ⚫ ⚫ 6 months in unpacked/packed and powered-off state The maximum preservation duration is determined according to the preservation ⚫ specifications provided by drive vendors. For details, see the manuals provided by drive vendors.
Page 77
FusionServer 5288 V5 Server Technical White Paper 6 Product Specifications Item Description between the front and rear mounting bars. Ball bearing rail kit: applies to cabinets with a − distance of 610 mm to 914 mm (24.02 in. to 35.98 in.) between the front and rear mounting bars.
FusionServer 5288 V5 Server Technical White Paper 7 Software and Hardware Compatibility Software and Hardware Compatibility Use the Compatibility Checker to obtain information about the operating systems and hardware supported. ⚫ If incompatible components are used, the device may be abnormal. This fault is beyond the scope of technical support and warranty.
FusionServer 5288 V5 Server Technical White Paper 8 Safety Instructions Safety Instructions 8.1 Security 8.2 Maintenance and Warranty 8.1 Security General Statement ⚫ Comply with local laws and regulations when installing devices. These Safety Instructions are only a supplement. ⚫...
Page 80
FusionServer 5288 V5 Server Technical White Paper 8 Safety Instructions ⚫ Do not carry the weight that is over the maximum load per person allowed by local laws or regulations. Before moving or installing equipment, check the maximum equipment weight and arrange required personnel.
Page 81
FusionServer 5288 V5 Server Technical White Paper 8 Safety Instructions Figure 8-3 Wearing an ESD wrist strap ⚫ Exercise caution when using tools. ⚫ If the installation position of the device is higher than the shoulders of the installation personnel, use a vehicle such as a lift to facilitate installation. Prevent the equipment from falling down and causing personal injury or damage to the equipment.
FusionServer 5288 V5 Server Technical White Paper 8 Safety Instructions equipment being transported is always kept upright. Take necessary precautions to prevent collisions, corrosion, package damage, damp conditions and pollution. ⚫ Transport the equipment in its original packaging. ⚫ If the original packaging is unavailable, package heavy, bulky parts (such as chassis and blades) and fragile parts (such as PCIe GPUs and SSDs) separately.
FusionServer 5288 V5 Server Technical White Paper 9 System Management System Management The server uses the next-generation Intelligent Baseboard Management Controller (iBMC) to implement remote server management. The iBMC complies with IPMI 2.0 and provides highly reliable hardware monitoring and management.
Page 84
FusionServer 5288 V5 Server Technical White Paper 9 System Management Specifications Description Setting of boot device Supports out-of-band configuration for the boot device. Alarm management Supports alarm management and reports alarms using the SNMP trap, SMTP, and syslog service to ensure 24/7 operating.
FusionServer 5288 V5 Server Technical White Paper 10 Certifications Certifications Country/Region Certification Standards Europe WEEE 2012/19/EU Europe REACH EC NO. 1907/2006 Europe Safety: EN 62368-1:2014+A11:2017 EMC: EN 55032:2015+A11:2020 CISPR 32:2015+A1:2019 EN IEC 61000-3-2:2019+A1:2021 EN 61000-3-3:2013+A1:2019 EN 55035:2017+A11:2020 CISPR 35:2016 EN 55024:2010+A1:2015 CISPR 24:2010+A1:2015 ETSI EN 300 386 V1.6.1:2012...
Page 86
FusionServer 5288 V5 Server Technical White Paper 10 Certifications Country/Region Certification Standards EN 55032:2015+A11:2020 CISPR 32:2015+A1:2019 EN IEC 61000-3-2:2019+A1:2021 EN 61000-3-3:2013+A1:2019 EN 55035:2017+A11:2020 CISPR 35:2016 EN 55024:2010+A1:2015 CISPR 24:2010+A1:2015 ETSI EN 300 386 V1.6.1:2012 ETSI EN 300 386 V2.1.1:2016 RoHS:...
FusionServer 5288 V5 Server Technical White Paper A Appendix Appendix A.1 Chassis Label The label information and location are for reference only. For details, see the actual product. A.1.1 On the Front Top Figure A-1 Chassis head label Nameplate Certificate...
Page 89
FusionServer 5288 V5 Server Technical White Paper A Appendix Table A-2 Certificate description Description Order NOTE For details, see Figure A-4 and Table A-3. QC inspector Production date No. Barcode Figure A-4 Sample certificate No. Table A-3 Certificate No. Description Description The value for this digit is P, which is fixed.
Page 90
FusionServer 5288 V5 Server Technical White Paper A Appendix Description Letters A to H indicate 10:00 to 17:00. ⚫ ⚫ Letters J to N indicate 18:00 to 22:00. Letters P to Q indicate 23:00 to 24:00. ⚫ Indicates the serial number (two digits).
Page 91
FusionServer 5288 V5 Server Technical White Paper A Appendix A.1.2 Chassis Tail Label Figure A-6 Chassis tail label For details about the warning label, see Server Safety Information. A.1.3 Chassis Internal Label Figure A-7 Chassis internal label ⚫ The quick guide is located on the inside of the chassis cover. It describes how to remove the mainboard components, important components of the chassis, precautions, and QR codes of technical resources.
Page 92
FusionServer 5288 V5 Server Technical White Paper A Appendix Figure A-8 Example SN Table A-5 SN description Description ESN ID (two characters), which can only be 21. Material ID (eight characters), that is, the processing code. Vendor code (two characters), that is, the code of the processing place.
Page 93
FusionServer 5288 V5 Server Technical White Paper A Appendix Configuratio Max. 30° C (86° F) Max. 35° C (95° F) Max. 40° C (104° F) 6154/6151/6254 8270/8268 and 5118/5218, and processors not Gold other processors supported 6154/6151/6254 lower than 105 W...
Page 94
FusionServer 5288 V5 Server Technical White Paper A Appendix Configuratio Max. 30° C (86° F) Max. 35° C (95° F) Max. 40° C (104° F) ⚫ Built-in drives NVMe drives in ⚫ slots 32 to 35 PCIe SSD cards ⚫...
Page 95
FusionServer 5288 V5 Server Technical White Paper A Appendix Module Feature Description Rank Sparing Uses some memory ranks for backup to prevent the system from breaking down due to uncorrectable errors. Memory Address Parity Detects memory command and address Protection errors.
Page 96
FusionServer 5288 V5 Server Technical White Paper A Appendix Module Feature Description system availability. Error Injection Support Implements fault injection to verify RAS features. Machine Check Provides a software repair function to Architecture (MCA) rectify uncorrectable errors to improve system availability.
Page 97
FusionServer 5288 V5 Server Technical White Paper A Appendix Sensor Description Component CPUN VDDQ Temp CPU VDDQ temperature Mainboard N indicates the CPU number. The value is 1 or CPUN VRD Temp CPU VRD temperature Mainboard N indicates the CPU number.
Page 98
FusionServer 5288 V5 Server Technical White Paper A Appendix Sensor Description Component PCH VPVNN PCH VPVNN voltage Mainboard PCH PRIM 1V05 PCH PRIM voltage Mainboard CPUN VCCP CPU VCCP voltage Mainboard N indicates the CPU number. The value is 1 or...
Page 99
FusionServer 5288 V5 Server Technical White Paper A Appendix Sensor Description Component number. The value is 1 or CPUN Memory CPU memory status DIMMs of CPU N N indicates the CPU number. The value is 1 or FANN Status Fan status...
Page 100
FusionServer 5288 V5 Server Technical White Paper A Appendix Sensor Description Component RAID Presence RAID controller card RAID controller card presence LCD Status LCD health status LCD Presence LCD presence PS Redundancy Redundancy failure due to PSU removal NIC# Status...
Page 101
FusionServer 5288 V5 Server Technical White Paper A Appendix Sensor Description Component RAID PCIE ERR RAID controller card fault RAID controller card diagnosis health status IB$ TEMP IB adapter temperature IB card PCIe$ OP Temp PCIe card optical module PCIe card...
FusionServer 5288 V5 Server Technical White Paper B Glossary Glossary B.1 A-E ejector lever A part on the panel of a device used to facilitate installation or removal of the device. Ethernet A baseband local area network (LAN) architecture developed by Xerox Corporation by partnering with Intel and DEC.
Page 103
FusionServer 5288 V5 Server Technical White Paper B Glossary B.3 K-O A hardware device that provides public keyboard, video and mouse (KVM). B.4 P-T panel An external component (including but not limited to ejector levers, indicators, and ports) on the front or rear of the server.
Page 104
FusionServer 5288 V5 Server Technical White Paper B Glossary B.5 U-Z A unit defined in International Electrotechnical Commission (IEC) 60297-1 to measure the height of a cabinet or chassis. 1 U = 44.45 mm UltraPath A point-to-point processor interconnect developed by Interconnect (UPI) Intel.
FusionServer 5288 V5 Server Technical White Paper C Acronyms and Abbreviations Acronyms and Abbreviations C.1 A-E alternating current Advanced Encryption Standard New Instruction Set Address Resolution Protocol Advanced Vector Extensions backup battery unit BIOS Basic Input/Output System calendar day Conformite Europeenne...
Page 106
FusionServer 5288 V5 Server Technical White Paper C Acronyms and Abbreviations DDR3 Double Data Rate 3 DDR4 Double Data Rate 4 DDDC double device data correction DEMT Dynamic Energy Management Technology DIMM dual in-line memory module DRAM dynamic random-access memory...
Page 107
FusionServer 5288 V5 Server Technical White Paper C Acronyms and Abbreviations high availability hard disk drive high-performance computing HTTP Hypertext Transfer Protocol HTTPS Hypertext Transfer Protocol Secure iBMC intelligent baseboard management controller Industry Canada ICMP Internet Control Message Protocol Internet Data Center...
Page 108
FusionServer 5288 V5 Server Technical White Paper C Acronyms and Abbreviations LAN on motherboard media access control module management controller next business day NC-SI Network Controller Sideband Interface C.4 P-T PCIe Peripheral Component Interconnect Express power distribution unit physical layer...
Page 109
FusionServer 5288 V5 Server Technical White Paper C Acronyms and Abbreviations RJ45 registered jack 45 RoHS Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Serial Attached Small Computer System Interface SATA Serial Advanced Technology Attachment...
Page 110
FusionServer 5288 V5 Server Technical White Paper C Acronyms and Abbreviations TCP offload engine trusted platform module C.5 U-Z UDIMM unbuffered dual in-line memory module UEFI Unified Extensible Firmware Interface unit identification light Underwriter Laboratories Inc. Universal Serial Bus VCCI...
Need help?
Do you have a question about the FusionServer 5288 V5 and is the answer not in the manual?
Questions and answers