To Drain The Storage Tank With A Connected Pressureless Solar System - Daikin ETSX16P30EF Installer's Reference Manual

Hide thumbs Also See for ETSX16P30EF:
Table of Contents

Advertisement

15
|
Disposal

15.2.2 To drain the storage tank with a connected pressureless solar system

Installer reference guide
270
a Screw plug
b Sealing plug
c Screw plug with drain connection (optional fill and drain kit)
d Screw plug with drain connection (spillover connector)
NOTICE
You can only drain the storage tank from the drain connection, if an optional fill and
drain kit is available (described below). Otherwise, drain with a pump and a hose
through the solar return connection.
1 Switch the drain connection valve to shown position.
2 Place an appropriate tray under the drain connection to collect water spillage.
3 Remove the clip and sealing plug.
4 Insert the fill and drain kit and secure with the clip.
a Clip
b Sealing plug
c Fill and drain kit
5 Open the valve of the fill and drain kit.
6 Switch the drain connection valve to standard position.
a
1
b
2
c
d
3
1
3
b
a
2
4
c
a
5
EPRA14~18DAV3+W1 + ETSH/X(B)16P30+50EF
Daikin Altherma 3 H HT ECH₂O
4P679467-1A – 2022.07

Advertisement

Table of Contents
loading

Table of Contents