dafi Flow Comfort DC10 Lead Manual

Tap water filtration system

Advertisement

Quick Links

TAP WATER
filtration system
Flow Comfort DC10 Lead
*
100%
Polish
Brand
*Brand most frequently recommended and purchased among water filtering products. Source: Formaster S.A. based on
a survey conducted by Difference, nationwide sample of N=1000 people aged 18+, using CAWI method, December 2022.

Advertisement

Table of Contents
loading

Summary of Contents for dafi Flow Comfort DC10 Lead

  • Page 1 TAP WATER filtration system Flow Comfort DC10 Lead 100% Polish Brand *Brand most frequently recommended and purchased among water filtering products. Source: Formaster S.A. based on a survey conducted by Difference, nationwide sample of N=1000 people aged 18+, using CAWI method, December 2022.
  • Page 2: Table Of Contents

    Table of contents Specification Safety of use - important information Technical details of the filtration system Instalation Turning on the system Replacement of the D10 Lead filter cartridge Maintenance Filter Replacement Indicators Flow Meter User's Manual Technical specifications of the Flow Meter Instructions on disposal and environmental protection Terms and conditions of the warranty...
  • Page 3: Specification

    Specification • The compact construction of the filter allows for perfect optimization of tap water by reducing the content of lead, chlorine and undesirable substances. The use of the Flow Comfort filtration system improves the taste of drinking water. Water becomes clear and suitable for direct con sumption. The elements of the system are adjusted for installation in a cabinet under the sink.
  • Page 4: Instalation

    Instalation Contents of the packaging One DC10 Lead filter cartridge that reduces the content of lead, chlorine and undesirable substances. It improves the taste and smell of drinking water. 4" Head of the filter cartridge 3-way faucet or filtered water faucet Integrated, independent or flow meter filter replacement indicator Bracket and screws for installation on the wall T-pipe, flexible hose, adapter...
  • Page 5 Connecting the head with the filter cartridge Just before snapping the filter cartridge in the head, remove the protective cover. To remove the protective cover: Tear off the protection Remove the cover The deaeration hose, which is a part of the head, should be loosely led out and be outside of the head. Press the head onto the filter cartridge in a firm motion, pressing the entire surface evenly, so that no gap remains between the filter, and the head.
  • Page 6 Connecting the filtration system to the water installation • Connecting the filtration system to the water installation of the building must be carried out in accor- dance with the standards applicable at the particular location. In case of any doubts, the installation should be carried out by a qualified specialist.
  • Page 7 Examples of connection...
  • Page 8: Turning On The System

    Turning on the system 1. Before turning on the water supply, make sure that all the installation steps have been carried out correctly and all elements of the system have been properly connected. 2. Turn on filtered water on the tap. 3.
  • Page 9: Maintenance

    Maintenance • On a regular basis, check whether the system is leakproof and the hoses are not bent. If bent, the hoses must be immediately replaced. • Do not use aggressive cleaning agents, abrasive substances or cleaning solutions. Filter Replacement Indicators The integrated indicator (faucets: VITO, HERO) LED - Diode signaling filter wear status...
  • Page 10 Settings: SIZE: Type of the filter cartridge • D1 • D2 • D3 • DC10 Lead Functions of the multifunctional CHECK/RESET button: By short-pressing the key (for 1 sec): check the status of the filter cartridge, which is signaled in the following way: •...
  • Page 11: Flow Meter User's Manual

    Flow Meter User's Manual Application Water treatment system SENSOR INSTALLATION IS CARRIED OUT BY THE INSTALLER Installation of power supply batteries Slide off the battery compartment cover from the side of the flow meter housing, slide out the basket and insert the into it two AA alkaline batteries maintaining the correct polarity. Then slide the basket and replace the cover.
  • Page 12: Technical Specifications Of The Flow Meter

    Low battery warning When the battery capacity level is low, the Flow Meter generates an audible alarm, and a flashing empty battery symbol appears in the upper right corner of the LCD display. The alarm will be canceled when the batteries are replaced with new ones.
  • Page 13: Terms And Conditions Of The Warranty

    4. In case of detected factory defects and faults, the Customer should contact the importer directly in order to receive information on further proceedings: Dafi LLC 601 N Congress Ave Ste 201 Delray Beach, FL 33445 e-mail: support@dafi.us...
  • Page 16 Manufacturer: Dafi LLC 601 N Congress Ave Ste 201 Delray Beach, FL 33445 e-mail: support@dafi.us tel: 561-717-6782...

Table of Contents