Electrical Characteristics - Fujitsu ASYG09KGTA Design & Technical Manual

Hide thumbs Also See for ASYG09KGTA:
Table of Contents

Advertisement

10. Electrical characteristics

Model name
Voltage
Power
supply
Frequency
Max operating current *1
Starting current
Circuit breaker current
Power cable
Wiring
spec. *2
Connection cable *3
Limited wiring length
*1: Maximum operating current is the total current of the indoor unit and the outdoor unit.
*2: Selected sample based on Japan Electrotechnical Standards and Codes Committee E0005. As
the regulations of wire size and circuit breaker differ in each country or region, select appropriate de-
vices complied to the regional standard.
*3: Limit voltage drop to less than 2%. If voltage drop is 2% or more, increase cable conductor size.
AOYG07KGCA AOYG09KGCA AOYG12KGCA AOYG14KGCA
V
Hz
A
A
2.8
A
2
mm
2
mm
m
- 58 -
230 ~
50
9.0
3.5
4.8
15
1.5
1.5
21
10.5
6.4
10. Electrical characteristics