SENCO Air Compressor. The contents of this manual are based on the latest product information available at the time of publication. The manufacturer reserves the right to make changes in price, color, materials equipment, specifications or models at any time without notice.
Safety Warnings Read All Safety Warnings Before Using Air Compressor Hazard Potential Consequence Prevention Serious injury or death could Make sure the air compressor is occur if the air compressor is plugged into a properly Risk of not properly grounded. Your air grounded outlet which provides Electric Shock compressor is powered by...
Page 6
All hoses and fittings shall be suitable for site use at the maximum allowable working pressure of the portable compressor. Use only genuine SENCO® repair parts for your air compressor.
Page 7
Safety Warnings Read All Safety Warnings Before Using Air Compressor Hazard Potential Consequence Prevention Risk to Serious injury or death could Never inhale air from the air occur from inhaling compressed compressor either directly or Breathing air. The air stream may contain from a breathing device carbon monoxide, toxic vapors connected to the air...
Page 8
Safety Warnings Read All Safety Warnings Before Using Air Compressor Hazard Potential Consequence Prevention Risk from Risk of bodily injury from Always turn off air compressor moving parts. This air when not in use. Bleed pressure Moving Parts compressor cycles from the air hose and unplug automatically when the...
Compressor Features Motor/Pressure Switch Thermal Overload / Reset Air Intake Filter Air Compressor Pump Safety Relief Valve Air Tank Drain Valve Tank Pressure Gauge Outlet Pressure Gauge Pressure Regulator Discharge Line Electric Power Cord Ventilation Openings / Protective Shroud Quick Disconnect...
Page 10
Compressor Features This switch is used to start or stop the air 1) Motor/Pressure Switch: compressor. Moving the switch to the ON (1) position will provide automatic power to the pressure switch which will allow the motor to start when the air tank pressure is below the factory set cut-in pressure. When in the ON (1) position, the pressure switch stops the motor when the air tank pressure reaches the factory set cut-out pressure.
1. SENCO® DOES NOT RECOMMEND THE USE OF EXTENSION CORDS as this can create power loss and overheating of the motor. Use of an additional air hose is recommended rather than an extension cord.
Operation Pre-Start Checklist 1. Remove any moisture in the air compressor tank. Remove excessive pressure by pulling on the safety relief valve ring or with an air tool, then open the air tank drain valve in the bottom of the air tank.
Bleed the line by moving the switch to the has not unloaded pump head pressure. position. OFF (0) Defective motor, motor capacitor, motor/pressure Contact Senco Customer Service. switch, or check valve. Symptom 2. When in the ON (1) position, motor runs continuously. Probable Cause Remedy ...
Page 14
Symptom 8. Air blowing from inlet filter. Probable Cause Remedy Damaged inlet (reed) valve. Contact SENCO Customer Service. Symptom 9. Insufficient pressure at air tool or accessory. Probable Cause Remedy Pressure regulator knob not turned to high ...
EN IO 14121-1:2007, EN ISO 3744:1995, EN ISO 4871:2009, EN1012-1:2010, EN 60204-1:2006+A1:2009, EN286-1:1998 Signed by : Chris Klein Position: Director of Engineering Place of DOC: Senco Brands, Inc. 4270 Ivy Pointe Blvd., Cincinnati, Ohio 45245 On Date: September 4, 2014 Authorized Representative: Name: Peter van der Wel Address: Senco Brands B.V.