Download Print this page

Teleco TVPLA868AC2 Manual

230vac control unit with radio receiver to control one or two 230vac motors for adjustable slats
Hide thumbs Also See for TVPLA868AC2:

Advertisement

Quick Links

230VAC CONTROL UNIT WITH RADIO RECEIVER TO CONTROL ONE OR TWO 230VAC MOTORS FOR
EN
ADJUSTABLE SLATS
Product code
TVPLA868AC2
TVPLA916AC2
M
M
M
230Vac
230Vac
230Vac
230
Vac
Independent or synchronized control of motor outputs.
Self-learning procedure for limit switches and working times.
M
TVPLA868AC2-AC2B
24Vdc
This document is the property of Teleco Automation Srl, which reserves all reproduction and copyrights
TELECO AUTOMATION SRL
Via dell'Artigianato, 16 - 31014 Colle Umberto (TV) ITALY
TELEPHONE: +39.0438.388511 - www.telecoautomation.com
(h = 74mm)
(h = 74mm)
M
230Vac
/
M
M
M
230Vac
230Vac
230Vac
/
M
M
M
24Vdc
24Vdc
24Vdc
M
24Vdc
TVPLA868AC2B
TVPLA916AC2B
I n p u t s f o r r a i n , w i n d a n d
temperature (for ice) sensors.
Combination of rain and temperature
sensors to detect snow.
LED CARD (optional) to control the
1-colour, RGB or RGBW 12/24Vdc
LED lights.
DOC.: T588.10_EN
(h = 50mm)
(h = 50mm)
DATE: 25/07/20

Advertisement

loading
Need help?

Need help?

Do you have a question about the TVPLA868AC2 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Teleco TVPLA868AC2

  • Page 1 Self-learning procedure for limit switches and working times. 24Vdc 24Vdc 24Vdc 24Vdc LED CARD (optional) to control the 1-colour, RGB or RGBW 12/24Vdc LED lights. TVPLA868AC2-AC2B DATE: 25/07/20 DOC.: T588.10_EN 24Vdc This document is the property of Teleco Automation Srl, which reserves all reproduction and copyrights...
  • Page 2: Further Details

    To prevent infiltration of water, wire the product as follows: The manufacturer, Teleco Automation s.r.l, declares that the type of radio equipment is compliant with Directive 2014/53/ EU. The full text of the EU compliance declaration is available at the following Internet address: www.telecoautomation.
  • Page 3 MOTOR 2 (CLOSE) WIND SENSOR (BROWN) Optional LED CARD WIND SENSOR (BLUE) 5A Fuse LED CARD power (only in TVPLA868AC2 version) RAIN SENSOR (WHITE, +12Vdc) supply (12-24Vdc) RAIN SENSOR (BLUE, SIGNAL) RAIN SENSOR (YELLOW, GND) Attention! The 230Vac input of the electronic board and the...
  • Page 4: Motor Configuration

    MOTOR CONFIGURATION: Identify the correct product application from the 3 given below and follow the relative configuration procedure. Attention: if the wrong application is selected, the configuration procedure must be repeated for the correct application. PERGOLA WITH 1 MOTOR 1. MOTOR CONFIGURATION keep pressed 5 s) L3 flashes...
  • Page 5 PERGOLA WITH 2 SYNCHRONIZED MOTORS 1. MOTOR CONFIGURATION keep pressed 5 s) L3 flashes Continuous sound DIP4=OFF Press P1 and P2 simultaneously DIP5=ON and hold for 5 s (*) Maximun time with the key pressed 90s. L2 flashes Check that movement stops when the limit switch is Closing reached (L2 flashes).
  • Page 6 PERGOLA WITH 2 INDEPENDENT MOTORS 1. MOTOR 1 CONFIGURATION keep pressed 5 s) L3 flashes Continuous sound DIP4=OFF Press P1 and P2 simultaneously DIP5=OFF and hold for 5 s (*) Maximun time with the key pressed 90s. L2 flashes Check that movement stops when the limit switch is Closing reached (L2 flashes).
  • Page 7 3. SELF-LEARNING OF LIMIT SWITCHES MOTOR 1 first, then MOTOR 2 < 1 s complete keep pressed 5 s) opening complete closing Press P1 and P2 simultaneously twice in quick succession and hold them the second time for 5 s DO NOT change the DIP configuration.
  • Page 8 TRANSMITTERS Transmitter with built-in light sensor 0 % (Closed) (see product instructions for details) 33 % 66 % 1 - Light sensor 100 % (Open) 2 - OPEN button Open (hold-to-run) 3 - CLOSE button 7/42 STOP 4 - Light level memorization button GREEN MOUSE CHANNEL 5 - Activation/deactivation light control button...
  • Page 9 RADIO CODES MEMORIZATION P1 or P2 If the system is configured as pergola with 2 independent motors, it associates memorization procedure using P1 to motor 1 and memorization procedure using P2 to motor 2. Note: the same radio code can in any case be associated with both motors. In the other configurations memorization is possible using either P1 or P2.
  • Page 10 SENSORS RADIO CODE MEMORIZATION P1 o P2 The condition of a full memory is signaled with 3 slow beeps. P1 or P2 TYPE OF MEMORIZATION continuos keep sound pressed ** WIND SENSOR Activate the sensor. Refer to instruction’s (TVSW868A03 only wind) sensor.
  • Page 11 REMOTE MEMORIZATION OF OTHER RADIO CODES REMOTE DELETION OF A RADIO CODE Note: The button P3 is located inside the transmitter. The added radio code will have the same functions as the Note: The button P3 is located inside the transmitter. If the radio code was code used for memorization.
  • Page 12 ALARMS PRIORITY The following alarms are ordered in a sequence of precedence, from highest priority to lowest priority. Factory setting SURVIVAL ALARM ACTIVATED ALARM ACTIVATED when What happens with ALARM ACTIVATED ALARM NOT ACTIVE when it does not receive a signal from the sensor The control unit directs the profiles to 50% of the entire opening.
  • Page 13 Factory setting SNOW CONDITION DEACTIVATED To manage the alarm associated with snow, the temperature (par. 4.6) and the rain sensors (par. 4.4) must be both activated. ALARM ACTIVATED when What happens with ALARM ACTIVATED ALARM NOT ACTIVE when The control unit tilts the slats to 66% of full opening. The control The measured temperature is below 2 °C The measured temperature is above 3 °C or and rain has been detected.
  • Page 14 Factory setting AFTER RAIN ACTIVATED System operation AFTER rain alarm (draining of water): once the rain alarm has ended, for the following 6 hours the control unit, upon receiving an automatic movement command from the transmitter, will tilt the pergola slats to 33% to allow water to drain off. For 4 minutes the control unit can only execute hold-to-run commands, thereby exiting from the alarm status.
  • Page 15 CHANGE OF THE AUTOMATIC ALARM ANGLES Use the following procedures to change the default angles of the pergola slats associated with the alarms. The system must have been configured and at least one transmitter memorized. keep pressed P1 or P2 * (5 s) continuous sound...
  • Page 16 TROUBLESHOOTING (WHAT TO DO IF…) Problem Solution The system needs to be programmed, see section 2. At power-on, the control unit does not move the motors and emits no warning. L3 flashes and an intermittent sound starts after configuration. Repeat the procedure. At the end of it DO NOT change the DIP4-5 setting. P1 and P2 must be pressed simultaneously.
  • Page 17 TECHNICAL SPECIFICATIONS Power supply 230Vac Max. power for each output 350W Fuse (cartridge) 5A (time-lag, 5x20) Operating temperature range -20° / +45°C Reception frequency 868.3MHz / 916MHz Radio memory capability (transmitters) Rain sensor power supply 12 Vdc (max.100mA) Anemometer 4 pulses/rotation (ANEM4) Temperature probe NTC (R=10Kohm;...
  • Page 18 LAY OUT AND FIXING MEASURES TVPLA868AC2 TVPLA868AC2 LED lights 230Vac LED lights power supply power supply 230Vac Sensors Sensors Temp. 12/24Vdc TVPLA868AC2B TVPLA868AC2B 230Vac Sensors power supply 70 mm Product 56 mm fastening holes (TVPLAxxxAC2) 32 mm (TVPLAxxxAC2B) 56 mm...
  • Page 19 TEMPERATURE sensor (wireless ACCESSORIES LED CARD to control the 1-colour, RGB or RGBW 12/24Vdc LED lights. (optional only in TVPLA868AC2 version) TVSTRD00PSI24 - LED 1-colour Independent or simultaneous control of 3 outputs. 12/24Vdc power supply (60W per output). TVRGB00PSI24 - LED RGB (red, green, blue) 12/24Vdc power supply (60W per output).
  • Page 20 Tel. +33.(0)472.145080 Tel. +33.(0)472.145080 Tel. +49.(0)8122.9563024 Tel. +49.(0)8122.9563024 Tel. +32.67561967 Tel. +32.67561967 Tel. +61.(07)5502.7801 Tel. +61.(07)5502.7801 info@telecoautomation.com info@telecoautomation.com info@telecofrance.com info@telecofrance.com info.de@telecoautomation.com info.de@telecoautomation.com info@telecoautomation.be info@telecoautomation.be info@telecoautomation.com.au info@telecoautomation.com.au This document is the property of Teleco Automation Srl, which reserves all reproduction and copyrights...

This manual is also suitable for:

Tvpla916ac2Tvpla868ac2bTvpla916ac2b