Omega OF610FX Instruction Manual page 13

Freestanding cooker
Table of Contents

Advertisement

Installation Instructions
Changing the Nozzle
1. Use a screwdriver to remove and install the nozzle as in Figure 3.
2. Remove the nozzle (figure 4) from the burner with nozzle driver and install a new nozzle (Figure 5).
Ventilation of Room
This product requires adequate ventilation. Ensure that there is proper ventilation when installing the appliance.
Reduced Gas Flow Rate Setting for Hob Taps
1. Ignite the burner that is to be adjusted and turn the knob to the reduced position.
2. Remove the knob from the gas tap.
3. Use an appropriately sized screwdriver to adjust the flow rate adjustment screw. For LPG (butane-pro pane) turn the
screw clockwise. For natural gas, turn the screw counter- clockwise once.
4. The normal length of a straight flame in the reduced position should be 6-7 mm.
5. If the flame is higher than the desired position, turn the screw clockwise. If it is smaller turn anticlockwise.
6. For the last control, bring the burner both to high-flame and reduced positions and check whether the flame is on or off.
Depending on the type of gas tap used in your appliance the adjustment screw position may vary.
To adjust your oven acc. to the gas type, make the adjustment for reduced flame carefully by turning with a small
screwdriver as shown below on the screw in the middle of the gas cocks as well as nozzle changes (figure 6).
Figure 3
Room size
Smaller than 5 m³
Between 5 m³ - 10 m³
Bigger than 10 m³
In basement or cellar
Figure 5
Figure 4
Ventilation opening
min. 100 cm²
min. 50 cm²
no need
min. 65 cm²
Figure 6
13