How to Start and Stop the Generator

4.7.1
How to Start and Stop the Generator (Control Panel)
The start/stop rocker switch is the only functional component on the generator control panel (and optional
remote-control panel) used to start and stop the generator. The start/stop rocker switch is a three-position
switch with momentary contacts in the START and STOP positions and a stationary contact in the NORMAL
center position. This position allows the generator to run once started and enables one or more remote
start/stop panels to control the start/stop functions of the generator.
10.
To start the unit, first turn the DC circuit breaker on.
11.
Press the rocker switch to the START position and release it.
NOTE: There is a delay of a few seconds after the DC breaker is turned on, while the ECU self-tests, before the
generator set responds.
The switch returns to its center position. The LEDs sequence momentarily from left to right. The fuel pumps
run (4-6 seconds). Then, the engine will crank and start. A
running.
12.
To stop the unit, press the rocker switch to the STOP position and release it. The STOP position stops the
engine in normal operation. If an emergency stop is required, turn off the DC circuit breaker.
NOTE: The STOP position is also used to prime the fuel system when necessary. See 4.6
System
.
13.
The
green
LED goes out indicating the engine has shut down.