Bryant 395CAV Series Installation, Start-Up, And Operating Instructions Manual page 10

Upflow gas-fired induced-combustion furnaces
Table of Contents

Advertisement

THERMIDISTAT
N/A
O/W2
N/A
Y1/W2
HEAT STAGE 1
W/W1
Y/Y2
COOL STAGE 1
G
FAN
R
24 VAC HOT
DHUM
DEHUMIDIFY
24 VAC COMM
C
HUM
HUMIDIFY
B
N/A
S1
OUTDOOR
SENSOR
S2
CONNECTION
Fig. 10—Single-Stage Furnace with 1-Speed Air Conditioner
THERMIDISTAT
N/A
O/W2
COOL STAGE 1
Y1/W2
HEAT STAGE 1
W/W1
Y/Y2
COOL STAGE 1
G
FAN
R
24 VAC HOT
DHUM
DEHUMIDIFY
24 VAC COMM
C
HUM
HUMIDIFY
B
N/A
S1
OUTDOOR
SENSOR
S2
CONNECTION
Fig. 11—Single-Stage Furnace with 2-Speed Air Conditioner
—10—
FURNACE
1-SPEED
CONTROL
AIR CONDITIONER
Y1
W
Y
Y/Y2
G
R
DHUM
COM
C
HUM
HUMIDIFIER
(24 VAC)
OUTDOOR
SENSOR
See notes 5, 7, and 10
FURNACE
2-SPEED
CONTROL
AIR CONDITIONER
Y1
Y1
W
Y2
Y/Y2
G
R
R
DHUM
C
COM
HUM
HUMIDIFIER
(24 VAC)
OUTDOOR
SENSOR
See notes 5, 8, and 10
A99435
A99436