Rs232 Hex Commands - Hitachi UHD8610PC Manual

Uhd 86” interactive flat panel display
Table of Contents

Advertisement

Command
GETTOTALSPACE
GETFREESPACE
SAVEMODELINFO
SETSCHEDULER
GETSCHEDULER
SETSCHEDULEOP
GETSCHEDULEOP

RS232 HEX Commands

Protocol Test Steps
• Before testing, please know the board type you have. There are two types of board. The UART 0 and UART
1 connections of the these boards are explained below:
1. RJ12 is connected to UART 0, DSUB9 is connected to UART 1. Therefore, UART 0 and UART 1 could
be tested separately in this type of the board
2. RJ12 and DSUB9 both are connected to UART 0. UART 1 is supported for OPS module but not
reachable. Therefore, only UART 0 could be tested in this type of the board.
• Activate HEX protocol on Display.
a. Enter Signage Settings Menu.
b. Change ASCII option to HEX in UART 0 or UART 1 sub-menu item
• Open any serial port communications program (e.g Realterm). Configure serial communication settings as
below:
Baud Rate
: 19200 for UART0, 9600 for UART1
Parity
: None
Data Bits
: 8
Stop Bits
: 1
Handshake
: None
• Note that UART0 default value: ASCII, UART1 default value: HEX
In the tables given below, XY represents are variable byte.
All byte values are hexadecimal.
Error Responses
• NAK reply: 15
• Error reply: 1C 00 00 When the display cannot execute the received command for any reasons, it returns
SIGNAGE SETTINGS COMMANDS
Description
get total usb space
(in MB)
get free usb space
(in MB)
saves model name
and sw version to a
removable device
enables/disables
scheduler
get scheduler enabled/
disabled
set scheduler
parameters
get scheduler
parameters
When the display cannot understand the received command, it returns this value. In
such a case, check the sending code and send the same command again.
this value. In such a case, check the sending code and the setting status of the display.
English - 32 -
Parameter
no parameter
no parameter
no parameter
string n (ON, OFF)
no parameter
string n ( on time_off time_
source in format: hh:mm_
hh:mm_source )
no parameter
Return
#*The total space is ... MB
#*The total space is ... MB
#*Model info is saved
OR
#*No Removable drive is
connected
(If there is no device connected)
#*The scheduler is set to .... (ON,
OFF)
#*The scheduler is .... (ON, OFF)
#*Schedule parameters are ... (set/
not set).
#*Scheduler on/off time and
source is: ......
(hh:mm_hh:mm_source)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Uhd8610Uhd8610aepcUhd8610ae

Table of Contents