Manual overrides
Prior to installation of the control system, or in case a problem occurs with the
control system or the network, it is possible to control the loads attached to the
8-Channel Adaptive Phase Dimmer through several methods:
Override scene
The module override scene is stored in the module itself and does not
require interaction from the control system.
The default setting for this override scene is all loads on at 100%.
The override scene settings can be changed using the buttons on the
front of the module (see the "Channel and Module Override" section
above) or Composer Pro.
Module Override button
Pressing the Module Override button toggles the attached loads
between the stored override scene and all loads off.
Auxiliary override contacts
The Aux In and Aux Out terminals on the 8-Channel Adaptive Phase
Dimmer can be wired to a standard line-voltage toggle switch installed
in a hidden but convenient location, such as a closet.
Each time the attached switch is flipped, the 8-Channel Adaptive
Phase Dimmer will toggle between the stored override scene and all
loads off.
If desired, a single toggle switch can be wired to the Aux In contact on
multiple Control4 Panelized Lighting modules, but all modules sharing
an auxiliary override switch must be on the same electrical phase.
The desired location of the auxiliary override switch can be defined
in Composer Pro for each module. This information will appear in the
Module Report generated by Composer Pro.
Channel Override buttons
The Channel Override buttons on the front of the module provide
individual control of each load attached to the 8-Channel Adaptive
Phase Dimmer. Click the specific Channel Override button to toggle
the load between its preset level and off. Press and hold the specific
Channel Override button to ramp/fade the load (if dimmable).
Troubleshooting
Symptom
Verify that the circuit breaker is on.
Module does not
power on
Verify that Line 1 in is connected to the power.
Load does not turn on
Verify that the load is wired to the proper channel
terminal.
Verify that the channel is not in a fault condition (see
"Faults" section above).
Verify that the light bulb is not burned out.
Loads do not turn off
Verify that the jumpers that connect the black terminal
block to the red terminal blocks have been removed.
Module overheats
Verify that the load ratings have not been exceeded.
Verify that the module is receiving proper ventilation.
Additional resources
The following resources are available for more support.
Control4 Knowledgebase and forums
Control4 Technical Support
Control4 website at
www.control4.com
Composer Pro documentation in various formats available at
Warranty and legal information
Find details of the product's Limited Warranty and other safety, patent, and legal