C4-FPD120 Forward Phase Dimmer
Introduction
The Control4® Forward Phase Dimmer operates independently or as part of a
Control4 home automation system. It installs in a standard wall box using typical
wiring standards and communicates to the Control4 system using a wireless
connection.
Box Contents
Forward Phase Dimmer
Wire Nuts
Warranty Card
Specifications and Supported Load Types
The specifications are described below.
Model Number
Power Requirements
Power Consumption
Load Types and Ratings
Supported Load Types
Maximum Load
Incandescent (Tungsten)
Halogen
Fluorescent*
Compact Fluorescent (CFL)*
LED*
Minimum Load (with neutral)
Incandescent (Tungsten)
Halogen
Fluorescent*
Compact Fluorescent (CFL)*
LED*
Forward Phase
Dimmer
Installation Guide
(this document)
C4-FPD120-xx
120 VAC +/-10%, 50/60 Hz
This device can function with or without a
neutral AC connection depending on load type.
See load types and wiring diagrams below.
When wired without a neutral, loads may
appear dimmer.
450mW
Incandescent; Halogen; Magnetic (Iron Core,
Inductive) Low Voltage (MLV) transformers;
Forward Phase Dimmable Fluorescents,
Compact Fluorescents, and LEDs.
1 Gang
2 Gang
1000W
800W
1000W
800W
500W
500W
500W
500W
200W
200W
4.5W
4.5W
4.5W
4.5W
4.5W
Minimum Load (without neutral)
Incandescent (Tungsten)
Halogen
Fluorescent*
Compact Fluorescent (CFL)*
LED*
Operational Temperature
Humidity
Storage
Control Communications
Wallbox Volume
Weight
Shipping Weight
* NOTES:
(1) The maximum and minimum load requirements for fluorescent, CFL
and LED loads can vary greatly depending upon the specific fixture and/
or bulb being used. At higher wattages, these load types have significant
in-rush current which can trip the protection circuitry on the device. At
low wattages, some CFL and LED loads will not be able to completely
shut off.
(2) In both cases, the quality and performance of these load types varies
greatly from manufacturer to manufacturer. When using these load types,
we recommend testing in advance. If problems are found, simply changing
to a different bulb manufacturer may solve the problem.
(3) Additionally, we do not recommend the use of fluorescent, CFL, or
LED loads without a neutral wire connected to the dimmer due to the
capacitive nature of these load types.
Warnings and Considerations
WARNING!
product. Improper use or installation can cause SERIOUS INJURY, DEATH
or LOSS/DAMAGE OF PROPERTY.
ATTENTION!
réparer ce produit. Une mauvaise installation ou utilisation peut entraîner
des blessures graves, décès ou perte / dommages à la propriété.
WARNING!
ATTENTION!
WARNING!
3+ Gang
Code (NEC) requirements. DO NOT rely solely upon the yoke plate's
600W
contact with a metal wallbox for adequate grounding. Use the device's
ground wire to make a secure connection to the safety ground of the
600W
electrical system.
500W
ATTENTION!
500W
de l'électricité (NEC). Ne comptez pas uniquement au contact de la
plaque avant avec un boîtier mural métallique pour la mise à la terre
200W
adéquate. Utilisez cet appareil à la terre de l'appareil pour établir une
connexion sécurisée au système électrique.
IMPORTANT!
accordance with all national and local electrical codes.
IMPORTANT!
consult a qualified electrician.
Environmental
32˚ F - 104˚ F (0˚ C - 40˚ C)
All load ratings are based on an ambient
temperature of 25˚ C.
5% to 95% non-condensing
-4˚ F - 158˚ F (-20˚ C - 70˚ C)
Miscellaneous
ZigBee, IEEE 802.15.4, 2.4 GHz, 15-channel
spread spectrum radio
5.75 cubic inches
0.12 lb. (0.05 kg)
0.18 lb. (0.08 kg)
Turn OFF electrical power before installing or servicing this
Coupez l'alimentation électrique avant d'installer ou de
This device must be protected by a circuit breaker (20A max).
Cet appareil doit être protégé par un disjoncteur (20A max.)
Ground this device in accordance with the National Electric
Cet appareil doit être en conformité avec le Code national
This device must be installed by a licensed electrician in
If you are unsure about any part of these instructions,
25W
25W
N/A
N/A
N/A

Advertisement

loading

Summary of Contents for Control 4 C4-FPD120

  • Page 1 32˚ F - 104˚ F (0˚ C - 40˚ C) All load ratings are based on an ambient Supported Model temperature of 25˚ C. Humidity 5% to 95% non-condensing C4-FPD120 Forward Phase Dimmer Storage -4˚ F - 158˚ F (-20˚ C - 70˚ C) Miscellaneous Introduction Control Communications ZigBee, IEEE 802.15.4, 2.4 GHz, 15-channel...
  • Page 2 IMPORTANT! Not grounding this product, as described in the “Warnings Use this device only with copper or copper-clad wire. Do IMPORTANT! and Considerations” section, may result in an installation less immune to not use aluminum wiring. This product has not been approved for use with damage caused by electrical disturbances, such as ESD or lightning, and aluminum wiring.
  • Page 3 ™ Figure 3. Dimmer Actuator Bar About this Document Actuator Bar Part Number: 200-00307, Rev C 7/30/2013 BN Sample Wiring Configurations Figure 4. Single Device Location, With Neutral Connection Button Tap Sequences The button tap sequences are defined in the table below. Button tap sequences that require a single (1) button should use the top-most button installed on the dimmer.
  • Page 4 Figure 6. Multiple Device Location Using Auxiliary Keypad, With Neutral Connection Figure 7. Multiple Device Location with Auxiliary Keypad, Without Neutral Connection Figure 8. Multiple Device Location Using Configurable Keypad, Neutral Required Copyright ©2013 Control4. . All rights reserved. Control4, the Control4 logo, the Control4 iQ logo and the Control4 certified logo are registered trademarks or trademarks of Control4 Corporation in the United States and/or other countries.