INOXPA DINAMIX SMX Installation, Service And Maintenance Instructions

Side entry agitator

Advertisement

Quick Links

INSTALLATION, SERVICE AND MAINTENANCE INSTRUCTIONS
SIDE ENTRY AGITATOR
DINAMIX SMX
Original Manual
20.073.30.01EN
(0) 2023/06

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DINAMIX SMX and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for INOXPA DINAMIX SMX

  • Page 1 INSTALLATION, SERVICE AND MAINTENANCE INSTRUCTIONS SIDE ENTRY AGITATOR DINAMIX SMX Original Manual 20.073.30.01EN (0) 2023/06...
  • Page 4: Table Of Contents

    8.6. Cleaning ..............................14 8.7. Disassembly and assembly of the agitator ....................16 9. Technical Specifications 9.1. Materials ..............................22 9.2. Other features ............................. 22 9.3. Dimensions ..............................23 9.4. arts list ..............................24 INOXPA S.A.U. 20.073.30.01EN · (0) 2023/06...
  • Page 5: Generalities

    The non-compliance of the prescribed indications in this manual means misuse of this gear on the technical side and the personal safety and this, exempt INOXPA of all responsibility in case of accidents and personal injuries and/or property damage. Also, excluded from the warranty all breakdowns caused by improper use of the gear.
  • Page 6: Safety

    Electric hazard Important instruction to prevent damage to the equipment and its functions ATTENTION 3.2. GENERAL SAFETY INSTRUCTIONS Read the instruction manual carefully before installing and starting the agitator. Contact INOXPA in case of doubt. 3.2.1. During the installation Technical Specifications chapter 9 should always be observed.
  • Page 7 The maximum operating conditions of the agitator should not be exceeded. Nor should the operating parameters for which the agitator was initially designed be modified without written authorisations from INOXPA. Do not leave loose parts on the floor. Do not disassemble the agitator until the switchboard has been disconnected. Remove the fuses and disconnect the power cable supplying the motor.
  • Page 8: General Information

    Each agitator has performance limits. The agitator was selected for a given set of mixing conditions when the order was placed. INOXPA shall not be held responsible for any damage that might be suffered or malfunctioning of the equipment if the information provided by the buyer is incomplete or incorrect.
  • Page 9: Installation

    • shipping documents, • quick installation guide or instruction manual, • instructions and servicing manual for the gear-motor when the agitator is supplied with a motor by INOXPA. 5.2. IDENTIFICATION OF THE AGITATOR The agitator is identified using a rating plate fixed onto the motor. The type of agitator and the serial number appear on the nameplate.
  • Page 10: Transport And Storage

    8º 14º 18º 25º 30º 40º 50º Max visc (cPS) 3000 3000 1500 1500 º º º º º º º º º º º º º º º º º º º º INOXPA S.A.U. 20.073.30.01EN · (0) 2023/06...
  • Page 11: Electrical Installation

    Force should never be applied to the end of the agitator shaft, as it can easily suffer permanent damage. ATTENTION Check the alignment of the agitator shaft with the half shaft once its assembly is completed. INOXPA S.A.U. 20.073.30.01EN · (0) 2023/06...
  • Page 12: Start-Up

    ATTENTION Do not modify the operating parameters for which the agitator was initially designed without written authorisation from INOXPA (risk of damage and user hazard). Follow the instructions for use and the safety requirements described in the instructions manual for the tank in which the agitator is mounted.
  • Page 13: Troubleshooting

    The attached table lists solutions to problems that may arise while operating the agitator. It is assumed that the agitator has been properly installed and that is has been selected correctly for the specific application. Contact INOXPA if technical assistance is required. Motor overload...
  • Page 14: Maintenance

    If the agitator is installed in a system with a CIP process its disassembly will not be required. If the automatic cleaning process is not provided, proceed to disassemble the agitator as indicated in the chapter 8.7. Disassembly and assembly of the agitator. INOXPA S.A.U. 20.073.30.01EN · (0) 2023/06...
  • Page 15 Maximum conditions during SIP process with steam or overheated water: a) Maximum temperature: 140°C / 284°F b) Maximum time: 30 min c) Cooling: sterile air or inert gas d) Materials: EPDM/PTFE (recommended) FPM (not recommended) INOXPA S.A.U. 20.073.30.01EN · (0) 2023/06...
  • Page 16: Disassembly And Assembly Of The Agitator

    Lock out the electrical switchboard or place a warning sign. Remove the fuses and take them to the workplace. 8.7.1. Disassembly of the agitator Once the motors have been disconnected, disassembly work on the agitator may begin. Remove the cover of the agitator. INOXPA S.A.U. 20.073.30.01EN · (0) 2023/06...
  • Page 17 Remove shaft key (61). 4. Remove drive • Unscrew cap nuts (54) and remove washers (53) and screws (52). • Separate drive (93) from lantern. • Remove the lantern protectors (47) by extracting the screws (52B). INOXPA S.A.U. 20.073.30.01EN · (0) 2023/06...
  • Page 18 Center the drive (93) on top of the lantern (04) and align the screw holes. • Insert the screws (52) with washers (53) from inside the lantern and screw in the cap nuts (54) with washers (53) from the drive side. INOXPA S.A.U. 20.073.30.01EN · (0) 2023/06...
  • Page 19 Push the seal closed and tighten the set screw making sure that the distance between the lock ring and the base plate is the one indicated in the following table: SMX-1 SMX-2 SMX-3 SMX-4 SMX-5 H (mm) 47,8 49,2 59,5 INOXPA S.A.U. 20.073.30.01EN · (0) 2023/06...
  • Page 20 Push the seal closed and tighten the set screw (55) making sure that the distance between the sleeve and the base plate is the one indicated in the following table: SMX-1 SMX-2 SMX-3 SMX-4 SMX-5 H (mm) 48,4 45,4 53,4 53,4 INOXPA S.A.U. 20.073.30.01EN · (0) 2023/06...
  • Page 21 Use a mallet to lightly tap on the impeller blades to tighten the impeller. 4. Lantern protector installation • Place the lantern protectors (47) on the lantern (04) aligning the lantern column holes with the protector’s slot. INOXPA S.A.U. 20.073.30.01EN · (0) 2023/06...
  • Page 22: Technical Specifications

    Speed Impeller Flow rate Weight Agitator Ø [mm] [kW] [rpm] Ø [mm] (kg) SMX-2/P 1.16-29007-400 0,75 SMX-2/P 1.16-22015-500 1000 SMX-2/P 1.16-31030-500 1300 SMX-2/P 1.16-36040-500 1650 SMX-3/P 1.16-32075-600 2500 SMX-4/P 1.16-320110-800 3800 SMX-5/P 1.16-280220-800 5200 INOXPA S.A.U. 20.073.30.01EN · (0) 2023/06...
  • Page 23: Dimensions

    0,55 SMX-2/W 1.16-28007-400 0,75 SMX-2/W 1.16-19011-500 Parallel shaft drives Agitator ØA ØB ØC ØD SMX-2/P 1.16-29007-400 0,75 SMX-2/P 1.16-22015-500 SMX-2/P 1.16-31030-500 1000 SMX-2/P 1.16-36040-500 1022 SMX-3/P 1.16-32075-600 1226 SMX-4/P 1.16-320110-800 1359 SMX-5/P 1.16-280220-800 1627 INOXPA S.A.U. 20.073.30.01EN · (0) 2023/06...
  • Page 24: Parts List

    Mechanical seal C/SiC/EPDM Spacer ring 1.4307 (AISI 304L) Base plate AISI 316L Lantern protection PETP Screw Screw Screw Washer Cap nut 1.4404 (AISI 316L) Lock nut Steel Lock washer Steel O-ring EPDM Gear motor INOXPA S.A.U. 20.073.30.01EN · (0) 2023/06...
  • Page 25 Mechanical seal support sleeve 1.4404 (AISI 316L) Hygienic tank flange 1.4404 (AISI 316L) Base plate 1.4404 (AISI 316L) Hygienic cap nut 1.4404 (AISI 316L) Screw Washer Set screw O-ring EPDM O-ring EPDM O-ring EPDM O-ring EPDM INOXPA S.A.U. 20.073.30.01EN · (0) 2023/06...
  • Page 28 How to contact INOXPA S.A.U.: Contact details for all countries are continually updated on our website. Please visit www.inoxpa.com to access the information. INOXPA S.A.U. Telers, 60 – 17820 – Banyoles – Spain Tel.: +34 972 575 200 – Fax: +34 972 575 502...