INOXPA 6100 Ex Series Installation, Service And Maintenance Instructions

Bottom mixer

Advertisement

Quick Links

INSTALLATION, SERVICE AND MAINTENANCE
ANNEX FOR EC ATEX REGISTERED EQUIPMENT UNDER DIRECTIVE
6100 Ex serie BOTTOM MIXER
The contents of this Annex complements the information included in the
instruction manual. The instructions of this Annex must be observed
whenever equipment registered under Directive 2014/34/EU is used.
This Annex is to be added to the manuals of the ATEX registered
components that form part of the assembly (e.g. driving, etc.).
INSTRUCTIONS
2014/34/EU:
1
Manual Original
03.600.30.04EN
(D) 2022/04

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 6100 Ex Series and is the answer not in the manual?

Questions and answers

Summary of Contents for INOXPA 6100 Ex Series

  • Page 1 INSTALLATION, SERVICE AND MAINTENANCE INSTRUCTIONS ANNEX FOR EC ATEX REGISTERED EQUIPMENT UNDER DIRECTIVE 2014/34/EU: 6100 Ex serie BOTTOM MIXER The contents of this Annex complements the information included in the instruction manual. The instructions of this Annex must be observed whenever equipment registered under Directive 2014/34/EU is used.
  • Page 2 03.600.30.07EN (0) 2022/11 EU Declaration of Conformity INOXPA, S.A.U. Telers, 60 17820 – Banyoles (Girona) Hereby declare under our sole responsibility that the machine TANK BOTTOM MIXER Designation Type ME 6100 Ixxxxxxxxx Ixxxxxxxxx From serial number Is in compliance with applicable provisions of the following directive:...
  • Page 3: Safety Instructions

    The maximum operating conditions of the mixer should not be exceeded. Nor should the operating parameters for which the mixer was initially designed be modified without written authorisation from INOXPA. • Under no circumstances should the limit values of working conditions in explosive atmospheres be exceeded.
  • Page 4: Guarantee

    The mixer was selected for working conditions in explosive atmospheres at the time the order was placed. INOXPA will not be responsible for any damage which may be caused if the information provided by the buyer is incomplete or incorrect (type of liquid, viscosity, RPM, classification of the potentially explosive zone, gas generated by the potentially explosive atmosphere, etc.).
  • Page 5: Table Of Contents

    1.2. Symbols used ......................2 1.3. General safety instructions ..................2 1.4. Guarantee ........................3 1.5. Instructions Manual ....................3 1.6. INOXPA Service ......................3 Table of Contents 2. Receipt, storage and transport 2.1. Receipt ........................6 2.2. Storage ........................6 2.3.
  • Page 6: Receipt, Storage And Transport

    C Db Figure 1.1.: ATEX CE marking on the nameplate. Should the marking on the machine not correspond with the order, please contact INOXPA immediately to explain the situation. The temperature class and the maximum surface temperature depend on the temperature of the product to be stirred and the ambient temperature.
  • Page 7: Identification, Description And Use

    The mixer was selected for working conditions in explosive atmospheres at the time the order was placed. INOXPA will not be responsible for any damage which may be caused if the information provided by the buyer is incomplete or incorrect (type of liquid, viscosity, RPM, classification of the potentially explosive zone, gas generated by the potentially explosive atmosphere, etc.).
  • Page 8 Contamination of the liquid means that the pump is not functioning properly and it must be inspected. For example, the sealing system may have leaks in the middle or be open due to insufficient backpressure of the washing liquid.
  • Page 9: Installation And Assembly

    4. Installation and assembly 4.1. INSTALLATION AND ASSEMBLY ATEX mixers are compact units and are ALWAYS supplied together with the driving. 4.2. LOCATION It is very important to be able to access the electric connection device of the mixer, even when in operation. It should be considered that during any operation of the electric connection equipment there may be a potentially explosive atmosphere, for which safe work permits should be issued.
  • Page 10 The control equipment should comply with the regulations in effect, as is stipulated by the electric safety standard, as well as the indications established by the ATEX driving manufacturer. Also install protection against driving overload suitable to the nominal driving instructions manual.
  • Page 11: Start-Up, Operation And Shutdown

    5. Start-up, operation and shutdown 5.1. START-UP Explosive atmospheres may be generated during the start-up of the mixer, for which safe work permits should be issued and this work should only be carried out by qualified or trained personnel. The work without product can generate a temperature in the mechanical seal superior of the allowed in the classified zone.
  • Page 12: Maintenance And Storage

    On requesting the spare parts of a mixer to operate in a classified zone, the order should explicitly indicate that these are for ATEX mixer and indicate the manufacturing number. In case of failing to do so, INOXPA will not be responsible for the mixer operating with parts which are inadequate for the classified zone where installed.
  • Page 13 INOXPA is not responsible for accidents or damage caused as a result of the non-fulfilment of the instruction manual and this Annex. Cleaning Before proceeding with the disassembly of the mixer it is necessary to clean it, on the inside as well as outside.
  • Page 14 9. Technical Specifications Temperature range. See section 2.1.

This manual is also suitable for:

Me-6100 ex

Table of Contents