Installation, Operation & Maintenance Manual RJ7.5 ODEL OLLING (Model 4015, 4115, & 4P14 Series 4-Post) 7,500 lbs Capacity 2311 South Park Rd, Louisville, Kentucky 40219 Email: Web site: sales@challengerlifts.com www.challengerlifts.com Office 800-648-5438 / 502-625-0700 Fax 502-587-1933 READ THIS MANUAL COMPLETELY...
Page 2
CAUTION Before using this product, read and fully understand the operating instructions and all decals on the product. This is necessary to prevent injury to the operator and damage to the product. Roll jack forward before moving vehicle on or off lift. ...
RJ7.5 Installation, Operation and Maintenance Manual NSTALLATION Install a ¼ NPT male quick disconnect coupling in air inlet of F.L.R. pre installed on jack. Match to shop fittings. Place jack assembly on lift rack rails Once side members are adjusted and jack is centered between the rails, tighten the (4) hex bolts (2 per side) to lock in place, Fig 2.
RJ7.5 Installation, Operation and Maintenance Manual Loss of power If for any reason the lift will not raise off the locks or the locks will not retract, consult factory authorized personnel. DO NOT OVERRIDE ANY SAFETY FEATURE IN AN ATTEMPT TO LOWER THE LIFT.
RJ7.5 Installation, Operation and Maintenance Manual Parts Breakdown Rev. 02/06/2020 RJ7.5-IOM-A...
Page 6
Z16777 Jack Capacity Decal IMPORTANT! Replace all worn, damaged, or broken parts with parts approved by Challenger Lifts Inc. or with parts meeting Challenger Lifts Inc. specifications. Contact your local Challenger Lifts Parts Distributor for pricing and availability. (Call Challenger Lifts Inc. (502) 625-0700 for the Parts Distributor in your area) Rev.
Page 7
RJ7.5 Installation, Operation and Maintenance Manual REVISIONS 02/06/2020- UPDATED FIG 1 TO INCLUDE 4115 MODELS Rev. 02/06/2020 RJ7.5-IOM-A...