Choke Control

The choke control is used for cold starts in order to
provide the engine with a richer fuel mixture.
For cold starts the control should be pulled up.

Fuses

Fuses are located on the right hand side of the
machine. They are accessed by tilting the seat
forward. Fuses are flat pin fuses type as used in
automobiles.
There are three fuses with ratings and functions:
1. 20 A, Primary fuse.
2. 7.5 A, Mower deck coupling.
3. 10 A, Accessories

Hour Meter

The hour meter displays the total operating time with
the blade activated, eliminating hours being added if
the key was accidentally left on.
To view the operating hours, turn the key to the ON
position and engage the blade switch. The clutch will
engage and the hours should be shown on the meter.
The display on the hour meter will turn on the oil can
icon after every fifty hours of use and will stay on for
two hours or until the meter is manually reset.
To manually reset the timer, turn the ignition key to the
RUN position and then engage and disengage the
blade switch five times at one second intervals.
22
CONTROLS
Choke control
Fuses
Hour meter
8065-004
8065-043
8065-004