  • Page 2: Before Starting

    1.2. Power up the router and DG-U100 control unit. Configure the channel frequencies, address code, and 315 antenna communication frequency. 2. Software Installation 2.1. Copy the Takstar DG-U100 software package to your computer or download it via our website at: https://icn.takstar.com/upload/downloadFile/DG-U100%E5%B1%80%E5%9F%9F%E7%B D%91%E8%BD%AF%E4%BB%B6.ZIP...
  • Page 3: Network Connection

    (via router LAN port), and enable the network interface. 4. Software Login 4.1. Once the connection is ready, open the Takstar DG-U100 wireless conference system app. Here you will see two login methods. a. Regular login: for regular users (see Section 7); usable only after registering the control unit through Password login.
  • Page 4: Device Management

    computer has multiple network interfaces. Please choose the correct network interface in use so that you can discover the control unit IP after login. 4.2. Device port number is automatically generated by computer and does not have to be changed. Click [Password login] to start configuration. 5.
  • Page 5 Change the Device ID (if necessary), click [Register device] and click [OK] to register. Note: Verify registration by doing a Regular login. A successful Regular login indicates that the device is successfully registered. 5.3. Receiver Channel Management Click [Receiver Channel Management] to enter the following page. Select [Receiver Channel Management] Channel Management Interface ①...
  • Page 6 ④ Enable EQ: check/uncheck the checkbox to enable/disable EQ; used to compare before-and-after sound effects. [Reset EQ] to set all EQ settings to default zeros. ⑤ Copy EQ to: copy the EQ settings of the current channel to one of the other three channels.
  • Page 7 meter on CU channel is full, while the audio signal meter, 315 signal meter and effective signal meter are full on DU, as shown below. CU LCD Channel Display DU LCD Display After syncing, adjust unit gain as appropriate and go back to Receiver Channel Management page to adjust EQ settings if necessary.
  • Page 8 Note: A. #1~7 under Camera settings correspond to the ID number set on the camera. Takstar wireless conference system supports linking up to 7 cameras at the same time (including multi-CU system) B. When camera tracking is enabled, only one delegate unit is allowed to speak.
  • Page 9 ⑨ Speed: the horizontal and vertical speed percentage of camera rotation; range: 0%-91%. ⑩ Camera direction adjustment and zeroing button: Long-press [Up/Down/Left/Right] to adjust the camera angle; short-press [Zero] to return the camera to 0 coordinates. ⑪ Zoom (Out/In): controls the focal length of the camera. ⑫...
  • Page 10 6. Floor Control Floor Control Interface ① Frequency: displays the channel and the frequency set by the channel. ② RSSI/Battery: displays the signal strength and battery power of the unit occupying the channel. ③ Priority: displays the priority of the unit occupying the channel. ④...
  • Page 11 Regular login Floor Control Interface Users can perform regular login by directly clicking the [Regular login] button or by waiting 30s to be automatically logged in. Regular login only provides Floor Control function. If the CU is not registered, the software will exit in 30s.