Specifications - Kenmore 87100 Service Manual

Table of Contents

Advertisement

MODEL NO.
Rated Power Consumption
Output
Frequency
Power Supply
Magnetron Cooling
Microwave Stirring
Rectification
Door Sealing
Safety Devices
Magnetron
High Voltage Capacitor
High Voltage Diode
Cavity Lamp
Tray
Overall Dimensions (W x D x H)
Oven Cavity Size (W x D x H)
Effective Capacity of Oven Cavity
Accessories
SWITCH MODE
CONDITIONS
DOOR OPEN
DOOR CLOSED
NOTE: Use the above switch chart with circuit diagram on page 4-2.
"•" represents the connection of the terminal of each switch.

SPECIFICATIONS

SWITCH CHART
PRIMARY
INTERLOCK
SWITCH
COM
NO
1-1
87100
1,500 W
900 W (*IEC 705 Rating standard)
2,450 MHz
120 V AC, 60 Hz
Forced Air Cooling
Turntable
Rectification Voltage Doubler Half-Wave
Choke Cover and Choke System
Thermostat:
°c
Open at 90
± 5
°c
Close at 75
± 5
Fuse(20A)
Primary Interlock Switch
Secondary Interlock Switch
Interlock Monitor Switch
2M246
1.0 µF, 2.1 KV AC
350 mA, 9.0 KV
125 V, 20 W
Tempered Safety Glass
1 /8
" x 15
5 /16
" x 12"
20
" x 14
" x 8
3 /8
1 /8
13
1.0 Cu.ft
Owner's Manual, Easy Use Chart
Glass Turntable, Rotating Ring
SECONDARY
INTERLOCK
SWITCH
COM
NO
°c
°c
"
7 /8
INTERLOCK
MONITOR
SWITCH
COM
NC

Advertisement

Table of Contents
loading

This manual is also suitable for:

767.8710000

Table of Contents