Roland MT-300S Midi Implementation Manual page 7

Roland mt-300s music player: supplementary guide
Hide thumbs Also See for MT-300S:
Table of Contents

Advertisement

■ Individual Parameters
Individual Parameter Transmission transmits data (or requests data) for one parameter as one exclusive message (one packet of "F0 ..... F7").
In Individual Parameter Transmission, you must use the Address and Size listed in the following "Parameter Address Map." Addresses marked at "#" cannot be used as starting addresses.
● System Parameters
Parameters related to the system of the device are called System Parameters.
Address (H)
Size (H)
Data (H)
40 00 00
00 00 04
0018-07E8
40 00 01#
40 00 02#
40 00 03#
* Refer to section 4. Supplementary material, "About tuning" (page 12).
40 00 04
00 00 01
00-7F
40 00 05
00 00 01
28-58
40 00 06
00 00 01
01-7F
40 00 7F
00 00 01
00
* Refer to "System exclusive messages related to Mode settings" (page 4).
40 01 10
00 00 10
00-40
40 01 11#
40 01 12#
40 01 13#
40 01 14#
40 01 15#
40 01 16#
40 01 17#
40 01 18#
40 01 19#
40 01 1A#
40 01 :#
40 01 1F#
* The sum total of voices in the voice reserve function must be equal to or less than the number of the maximum polyphony. The maximum polyphony of the MT-300s is 64. For compatibility
with other GS models, it is recommended that the maximum polyphony be equal or less than 24.
40 01 30
00 00 01
00-07
40 01 31
00 00 01
00-07
40 01 32
00 00 01
00-07
40 01 33
00 00 01
00-7F
40 01 34
00 00 01
00-7F
40 01 35
00 00 01
00-7F
* REVERB MACRO is a macro parameter that allows global setting of reverb parameters. When you select the reverb type with REVERB MACRO, each reverb parameter will be set to the most
suitable value.
* REVERB CHARACTER is a parameter that changes the reverb algorithm. The value of REVERB CHARACTER corresponds to the REVERB MACRO of the same number.
40 01 38
00 00 01
00-07
40 01 39
00 00 01
00-07
40 01 3A
00 00 01
00-7F
40 01 3B
00 00 01
00-7F
40 01 3C
00 00 01
00-7F
40 01 3D
00 00 01
00-7F
40 01 3E
00 00 01
00-7F
40 01 3F
00 00 01
00-7F
* CHORUS MACRO is a macro parameter that allows global setting of chorus parameters. When you use CHORUS MACRO to select the chorus type, each chorus parameter will be set to the
most suitable value.
Parameter
Description
MASTER TUNE
-100.0 - +100.0 [cent]
Use nibblized data.
MASTER VOLUME
0-127
(= F0 7F 7F 04 01 00 vv F7)
MASTER KEY-SHIFT
-24 - +24 [semitones]
MASTER PAN
-63 (LEFT) - +63 (RIGHT)
MODE SET
00 = GS Reset
(Rx. only)
127 = Exit GS
VOICE RESERVE
Part 10 (Drum Part)
Part 1
Part 2
Part 3
Part 4
Part 5
Part 6
Part 7
Part 8
Part 9
Part 11
:
Part 16
REVERB MACRO
00: Room 1
01: Room 2
02: Room 3
03: Hall 1
04: Hall 2
05: Plate
06: Delay
07: Panning Delay
REVERB CHARACTER
0-7
REVERB PRE-LPF
0-7
REVERB LEVEL
0-127
REVERB TIME
0-127
REVERB DELAY FEEDBACK
0-127
CHORUS MACRO
00: Chorus 1
01: Chorus 2
02: Chorus 3
03: Chorus 4
04: Feedback Chorus
05: Flanger
06: Short Delay
07: Short Delay (FB)
CHORUS PRE-LPF
0-7
CHORUS LEVEL
0-127
CHORUS FEEDBACK
0-127
CHORUS DELAY
0-127
CHORUS RATE
0-127
CHORUS DEPTH
0-127
CHORUS SEND LEVEL TO REVERB
MT 300s MIDI Implementation
Default Value (H)
Description
00 04 00 00
0 [cent]
7F
127
40
0 [semitones]
40
0 (CENTER)
***
02
2
06
6
02
2
02
2
02
2
02
2
02
2
02
2
02
2
02
2
00
0
00
0
04
Hall 2
04
4
00
0
40
64
40
64
00
0
02
Chorus 3
00
0
40
64
08
8
50
80
03
3
13
19
0-127
00 0
7

Advertisement