INSTALLATION AND OPERATING INSTRUCTIONS
I
INSTALLATION AND OPERATING INSTRUCTIONS
3
UF 80/100
ULTRA FINE
CARTRIDGE FILTER
INSTALLATION AND
OPERATING INSTRUCTIONS
Rainbow Pool Products
®
PO Box 2388, Mansfield Qld 4122
Telephone STD 61-7-3849 5385
Facsimile STD 61-7-3849 5384
Email: info@rainbowpoolproducts.com.au
Web: www.rainbowpoolproducts.com.au

Advertisement

Table of Contents
loading

Summary of Contents for fluidra ASTRAL POOL ULTRA FINE UF 80

  • Page 1 INSTALLATION AND OPERATING INSTRUCTIONS INSTALLATION AND OPERATING INSTRUCTIONS UF 80/100 ULTRA FINE CARTRIDGE FILTER INSTALLATION AND OPERATING INSTRUCTIONS Rainbow Pool Products ® PO Box 2388, Mansfield Qld 4122 Telephone STD 61-7-3849 5385 Facsimile STD 61-7-3849 5384 Email: info@rainbowpoolproducts.com.au Web: www.rainbowpoolproducts.com.au...
  • Page 2: Important Safety Precautions

    IMPORTANT SAFETY PRECAUTIONS ATTENTION INSTALLER: This guide contains important information about the installation, operation and safe use of this product. This information should be given to the owner and/or operator of this equipment after installation or left on or near the filter. ATTENTION USER: This manual contains important information that will help you in operating and maintaining this filter.
  • Page 3: General Overview

    GENERAL INSTALLATION INFORMATION. The following information should be read carefully as it outlines the proper manner of care and operation of your filter system. You can expect maximum efficiency and product life from you filtration system by following these instructions and taking the necessary preventative maintenance.
  • Page 4: Clamp Installation

    When performing hydrostatic pressure testing or when testing for external leaks of the completed filtration and plumbing system, ensure that the maximum pressure that the filtration system will be subject to DOES NOT EXCEED THE MAXIMUM WORKING PRESSURE OF ANY OF THE COMPONENTS CONTAINED WITHIN THE SYSTEM. In most cases the maximum working pressure will be sated on each component of the system.
  • Page 5: Starting Instructions

    PREPARING DIATOMITE FOR FILTER Your filter requires diatomaceous earth (D.E . or diatomite) for proper filtration and operation. Your filter elements must be pre-coated with this material in order to protect their surfaces and provide the most efficient filtering action. Refer to the table below for proper quantity to use with your filter.
  • Page 6 CLEANING ELEMENTS Clean the cartridges when the flow to the pool reduces or the pressure gauge increases by 10 - 15 psi. Stop the pump, close valves on the suction and return lines Open the air bleed valve (located in the filter lid) Allow all pressure to be relieved from system. Open the drain plug at base of the filter to drain the filter of water.
  • Page 7: Pump Priming

    PUMP PRIMING With the pump OFF, Remove the lid from the pump strainer and pour in approximately 1 gallon of water or until strainer is fully covered Replace the pump lid, ensuring it is fitted correctly If valve(s) have been installed on the pump suction line, close before filling strainer. Open again after lid has been securely fitted in place.
  • Page 8 obstruction in the line between the pool and the pump. PRESSURE REMAINS HIGH AFTER pressure remains high after backwash, BACKWASH backwash filter again, if still high, treat for conditions covered by LIMING UP above. MAINTAIN YOUR PRESSURE GAUGE The pressure gauge is an important part of the Check the operation of your pressure gauge in IN GOOD WORKING ORDER filter system.
  • Page 9: Warranty

    WARRANTY AstralPool Australia Pty Ltd (ABN 97 007 284 504) ("AstralPool") provides the following warranty in relation to its CL series cartridge filters ("Product"). The benefits of this warranty are in addition to any rights and remedies imposed by Australian State and Federal legislation that cannot be excluded.
  • Page 10 Examples of exclusions include but are not limited to:  Over tightening of locking ring or union fittings  Damage to element caused by use of high pressure water cleaners Commercial Installations On commercial installations, such as health clubs, motels/hotels and hydrotherapy facilities, the warranty is limited to parts and in field labour (within capital city metropolitan areas or 20 km radius of Authorised AstralPool Service Agents) for a period of 12 months from the date of purchase plus 30 days to allow for installation.