Indoor Unit Installation Drawings - Daikin FTX25KNV1B Installation Manual

Hide thumbs Also See for FTX25KNV1B:
Table of Contents

Advertisement

Indoor Unit Installation Drawings

A Mounting plate
B
Mounting plate
fixing screw
(field supply: M4 x 25L)
Front panel
50mm or more
from walls (on both sides)
Air filters
C
Titanium apatite photocatalytic
air-purifying filter (2)
Titanium apatite photocatalytic
air-purifying filter
English
The
A
mounting plate
should be installed on a
wall which can support the
weight of the indoor unit.
30mm or more from ceiling
Screws
M4 × 16L
The service lid is removable.
Opening method
1) Remove the service lid screw.
2) Pull out the service lid horizontally in
the direction of the arrow.
3) Pull down.
D
Wireless remote
controller
How to attach the indoor unit
Hook the hooks of the bottom frame
A
to the
mounting plate.
If the hooks are difficult to hook,
remove the front grille.
How to remove the indoor unit
Push up the marked area (at the
lower part of the front grille) to
release the hooks. If it is difficult to
release, remove the front grille.
Caulk
pipe hole
gap
with putty.
Appearance of
indoor units may
differ from some
models.
Service lid
F
Fixing screw for remote
controller holder
(field supply: M3 x 20L)
Bottom frame
Front grille
Cut thermal insulation
pipe to an appropriate
length and wrap it with
tape, making sure that no
gap is left in the insulation
pipe's cut line.
Wrap the insulation pipe with
the finishing tape from bottom
to top.
Before screwing the
remote controller
E
holder to the wall, make
sure that control signals
are properly received by
indoor unit.
E
Remote
controller holder
A
Mounting
plate
Hook
Mark (rear side)