AEMC instruments 1246 Quick Start Manual

Thermo-hygrometer data logger

Advertisement

Quick Links

Thermo-Hygrometer
Data Logger Model 1246
Quick Start Guide
ENGLISH
www.aemc.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 1246 and is the answer not in the manual?

Questions and answers

Summary of Contents for AEMC instruments 1246

  • Page 1 Thermo-Hygrometer Data Logger Model 1246 Quick Start Guide ENGLISH www.aemc.com...
  • Page 2 For recalibration, please use our calibration services. Refer to our repair and calibration section at www.aemc.com Serial #: Catalog #: 2121.73 Model #: 1246 Please fill in the appropriate date as indicated: Date Received: Date Calibration Due: ® Chauvin Arnoux , Inc.
  • Page 3 Thank you for purchasing the Thermo-Hygrometer Datalogger Model 1246. For best results from your instrument:  read these operating instructions carefully  comply with the precautions for use Information or useful tip. Battery. Magnet. The product has been declared recyclable after analysis of its life cycle in accordance with the ISO14040 standard.
  • Page 4 Close the battery compartment cover; ensuring it is completely and correctly closed. Connecting to a Computer ® The Model 1246 must be connected to DataView for full configuration. (For detailed setup instructions, see the User Manual in the USB drive that comes with the instrument.): ®...
  • Page 5 INSTRUMENT CONFIGURATION In addition to setting the instrument’s clock, other basic setup tasks include:  Enabling Bluetooth (can be done on the instrument or via DataView)  Setting measurement units to °F or °C (can be done on the instrument or via DataView) ...
  • Page 6 Note that the last measurement display selected is saved when the instrument is turned OFF.  Relative humidity (RH) is the ratio of the quantity of water vapor contained in a volume of air to the maximum quantity this same volume of air can contain at the current temperature.
  • Page 7 Repair and Calibration To ensure that your instrument meets factory specifications, we recommend that it be sent back to our factory Service Center at one-year intervals for recalibration, or as required by other standards or internal procedures. For instrument repair and calibration: You must contact our Service Center for a Customer Service Authorization Number (CSA#).
  • Page 8 01/18 99-MAN 100452 v1 Chauvin Arnoux ® , Inc. d.b.a. AEMC ® Instruments 15 Faraday Drive • Dover, NH 03820 USA Phone: (603) 749-6434 • Fax: (603) 742-2346 www.aemc.com...

Table of Contents