FINAL ASSEMBLY

1. Push the wires into the junction box.
2. Slide the fixture assembly onto the long fixture screws.
Tighten decorative nuts securely against fixture base.
3. Caulk the fixture base mounting surface with silicone
weather sealant.
4. Adjust lamp holder(s) as needed. Note: Loosen
the screws on the lamp heads before making any
adjustments. IMPORTANT: Do not rotate the lamp
holders more than 180° from the factory setting.
Decorative Nut
Lens
206150-03
Long Fixture Screw
Junction Box
Keep lamp heads at least 1.5"
(40 mm) from the sensor. Do
not allow the lamp heads to
block the lens.

TEST AND ADJUSTMENT

1. Turn on the circuit breaker and light switch.
Note: Sensor has a 1 minute warm up period before it
will detect motion. When first turned on, wait 30
seconds.
2. Turn the TIME control to the minimum position and
the LUX control to the (R) position. The security light
will switch on and remain on for a maximum of 60
seconds.
3. Aim the sensor toward the desired detection zone
by adjusting the elbow joint and swivel joint on the
sensor arm.
IMPORTANT: Loosen all lock nuts and screws on
sensor and lamp heads before making any adjust-
ments.
4. Have another person move across the center of the
area to be scanned and slowly adjust the angle of the
sensor arm until the unit senses the presence of the
moving person, causing the light to switch on.
5. Adjust the TIME control to desired setting.
6. To set the light level at which the light will automatically
switch "on" at night, turn the LUX control knob from day-
light (R) to night (ƒ). Wait for the desired surrounding
light level, then slowly turn the LUX control knob towards
daylight while someone walks across the center of the
area to be detected. When the light switches on, release
the LUX control knob. You may need to make further
adjustments to achieve your ideal light level setting.