Thank you for purchasing a Taylor® non-contact infrared thermometer. Please read this instruction manual carefully before use. Keep these instructions handy for future reference.
Please remember to keep the unit away from children and do not use it for safety related applications.
oF or oC switchable | Press the "0C/0F" key to switch between oF and oC temperature scales. |
Backlight | LCD Backlight: always on while the unit is on. |
Laser | To enable the laser, press the " " button while the unit is on. The " " icon appears on the LCD, indicating the laser is active. The laser sight will then operate when the Measurement button is pressed. To disable the laser, press the " " button while the unit is on. |
Auto Off | The unit will automatically turn off after 15 seconds of non-use to conserve battery power. |
Scan/Hold | When the Measurement button is pressed, the unit will scan for surface temperatures and update the reading on the LCD screen. When the Measurement button is released, the screen will hold the last reading. The maximum temperature reading appears in the bottom of the screen. (The maximum temperature reading will reset after each use.) |
EMC/RFI Readings may be affected if the unit is operated within a radio frequency electromagnetic field strength of approximately 3 volts per meter, but the performance of the instrument will not be permanently affected. |
The sensor lens is the most delicate part of the thermometer. The lens should be kept clean at all times. Take care when cleaning the lens, using only a soft cloth or cotton swab with water or medical alcohol, and allow the lens to fully dry before using the unit. Do not submerge any part of the thermometer. The thermometer should be stored at room temperature between -4~140°F (–20 to +60°C).
When the 'Low Battery' icon indicates the battery is low, the batteries should be replaced immediately with 2 AAA batteries. Please note: It is important to turn the instrument off before replacing the batteries, otherwise the thermometer may malfunction. Dispose of used batteries properly and keep away from children. Always replace both batteries at the same time; do not combine old and new batteries. Do not mix Alkaline, carbon-zinc (standard) or Nickel-Cadmium (rechargeable) batteries. Remove the batteries if the unit will not be used for a long period of time.
Measurement Range | -49 to +752 oF (-45 to +400 oC) |
Operating Range | 32 to 122°F (0 to 50°C) |
Accuracy (-49 to +32°F / -45 to 0°C range) | +/- 1.8oF + (.10 x (reading-32))°F +/- 1°C + (.10 x reading)°C |
Accuracy (+32 to +149°F / 0 to +65°C range) | +/- 1.8°F (+/-1°C) |
Accuracy (above +149°F / +65°C range) | +/- 1.5% of reading |
Emissivity | 0.95 fixed |
Resolution (-9.9~199.9°C) | 0.1°F / 0.1°C |
Response Time (90%) | 0.5 second |
Distance: Spot | 6:1 |
Battery Life | Approximately 16 hours |
Dimensions | 7.35×1.72×3.37 inches (186.8 x 43.6 x 85.7 mm) |
Weight | 0.37 lb (169 g) including batteries (2 AAA) |