3.2.2 Protection Class

Die Schutzklasse entspricht IP 67, wenn entweder das Kabel oder eine Schutzkappe montiert ist.

3.2.3 Connectivity

ARE i9x is connected via its M12, 5-Pin male A-coded plug. Power supply as well as communication is provided by ACM 9,
communication module. Do not use any other means of powering or communicating to ARE i9x other than an ACM 9
module, otherwise ARE i9x will be damaged. Do only use specified cables. ARE i9x uses a LED lit RFID symbol on its front
side to visually communicate its various states (standby, reading, successful read, no read, error, and so on...). When ARE i9x
is hooked up to ACM 9, the internal LED is switched to standby color. LED colors can be set by the user.
The Antenna AAN Xi9F is connected via a 3-pin connector on top of ARE i9x.
ARE i9x uses an external antenna AAN Xi9F. There is air core coil transponders like disks and ferrite core coil transponders
like glass tube transponders. It is important to understand the impact of orientation of transponders relative to AAN Xi9F.
Optimum orientation is parallel to the front side of the reader for disks and perpendicular for glass tube transponders. In
this orientation, the highest read range can be achieved.
Manual ACM9_ARE i9 release V10.docx
PIN 1 – +7V
PIN 2 – GND
PIN 3 – RX
PIN 4 – TX
PIN 5 – CGND
LED: Status Indikation
Kabel: M12, 5-Pin A-kodiert, Stecker und Buchse
Version: 10