Error Messages Coming Through From Are I9 - AEG ACM 9 Manual

Table of Contents

Advertisement

Manual ACM 9 - ARE i9 release
ACM 9 sets master input data to:
Hex:
23
ASCII:
Meaning
Change
counter

2.2.6 Error messages coming through from ARE i9

Other error messages can be generated by the reader, if the reader command is wrong. See section ARE i9 for a detailed
description of those error messages. Below are sample error codes, see section ARE i9 for full list.
Wrong reader instruction (Error code #00)
A wrong reader instruction triggers error code #00.
Hex:
04
ASCII:
Meaning:
Change
counter
ACM 9 sends this master input data:
Hex:
22
ASCII:
Meaning
Change
counter
Wrong reader instruction parameter (Error code #02)
A wrong reader instruction triggers error code #02.
Hex:
04
ASCII:
Meaning:
Change
counter
ACM 9 sends this master input data:
Hex:
22
ASCII:
Meaning
Change
counter
Manual ACM9_ARE i9 release V10.docx
00
15
23
<NAK>
'#'
Serial
interface
port
32
41
42
'2'
'A'
'B'
Serial
Instruction Text
interface
port
32
15
23
'2'
<NAK>
'#'
Serial
interface
port
32
41
4C
'2'
'A'
'L'
Serial
Instruction Text
interface
port
32
15
23
'2'
<NAK>
'#'
Serial
interface
port
36
37
'6'
'7'
Error Text
43
0D
'C'
<CR>
End
character
30
30
'0'
'0'
Error Text
47
4F
'G'
'O'
30
32
'0'
'2'
Error Text
Version: 10
Page: 13 / 51
0D
00
<CR>
End
character
00
...
0D
00
<CR>
End
character
20
30
<SP>
'0'
<CR>
character
0D
00
<CR>
End
character
...
...
0D
End
...

Advertisement