Wireless relay module

Advertisement

7. Position the wiring in the exit slot and reinstall the
5800RL's cover on the base.
Test the 5800RL module with the rest of the system.
DIP SWITCH POSITIONS
HOUSE
ID
2
3
4
5
-
-
-
0
-
1
-
-
-
-
2
-
-
-
ON
3
-
-
-
ON
4
-
-
ON
-
5
-
-
ON
-
6
-
-
ON
ON
7
-
-
ON
ON
8
-
ON
-
-
9
-
ON
-
-
10
-
ON
-
ON
11
-
ON
-
ON
12
-
ON
ON
-
13
-
ON
ON
-
14
-
ON
ON
ON
15
-
ON
ON
ON
" – " indicates "OFF"
1
2
SW-1
NOT USED
5800RL DIP Switch
Figure 4. DIP Switch Settings
RELAY and LED Operation
The 5800RL contains two relays (Figure 2) (SPDT, rated 2A.
28VAC/VDC) that may be used to activate remote sounders
and/or remote arm/disarm indicators. There are three LEDs
(green, yellow, red) located above the DIP switch and one
LED (red) located approximately in the center of the pc board.
The LEDs located above the DIP switch, indicate power and
relay activity. Refer to Figure 5. The RF Interference LED
monitors local radio frequency interference. If this LED is
continuously lit, the 5800RL should be relocated.
Relay
LED
Activates Upon...
A
Yellow
Alarm conditions as follows:
Steady ON = burglary alarm (NO contact
connects to COM)
Temporal ON = fire alarm (NO contact connects
temporal to COM)
OFF = no alarms present (NC contact connects
to COM)
ÊK3790V1UŠ
K3790V1 6/07 Rev. A
All manuals and user guides at all-guides.com
DIP SWITCH POSITIONS
HOUSE
ID
6
2
3
4
5
-
-
-
-
-
16
17
ON
ON
-
-
-
18
-
ON
-
-
ON
19
ON
ON
-
-
ON
20
-
ON
-
ON
-
ON
21
ON
-
ON
-
-
22
ON
-
ON
ON
ON
23
ON
-
ON
ON
-
24
ON
ON
-
-
25
ON
ON
ON
-
-
26
-
ON
ON
-
ON
27
ON
ON
ON
-
ON
28
-
ON
ON
ON
-
29
ON
ON
ON
ON
-
30
-
ON
ON
ON
ON
ON
31
ON
ON
ON
ON
SV6
7L
3
4
5
6
OFF POSITION
INDICATOR
2-6 SETS HOUSE ID
5800RF-003-V0
2 Corporate Center Drive, Melville, NY 11747
Copyright © 2007 Honeywell International Inc.
Relay
LED
B
Red
6
-
N/A
Green
ON
-
N/A
RF
ON
Inter-
-
ference
ON
Figure 5. Relay and LED Operation
-
ON
SPECIFICATIONS
-
Dimensions: 2-3/4"W x 4-15/16"H x 1-1/16"D
ON
(70mm x 125mm x 27mm)
-
Voltage:
12VDC 100mA or
ON
9VAC, 15VA (use ADEMCO 1332 or equivalent)
-
Current:
60mA
ON
Relay:
Two relays, each with choice of normally open (NO)
-
or normally closed (NC) operation.
ON
Operating Temperature: 0 - 50 ° C / 32 - 122 ° F
FEDERAL COMMUNICATIONS COMMISSION (FCC) STATEMENT
This equipment has been tested to FCC requirements and has been found
acceptable for use. The FCC requires the following statement for your
information:
This equipment generates and uses radio frequency energy and if not
installed and used properly, that is, in strict accordance with the
manufacturer's instructions, may cause interference to radio and television
reception. It has been type tested and found to comply with the limits for a
Class B computing device in accordance with the specifications in Part 15 of
FCC Rules, which are designed to provide reasonable protection against
such interference in a residential installation. However, there is no guarantee
that interference will not occur in a particular installation. If this equipment
does cause interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to
try to correct the interference by one or more of the following measures:
• If using an indoor antenna, have a quality outdoor antenna installed.
• Reorient the receiving antenna until interference is reduced or eliminated.
• Move the radio or television receiver away from the receiver/control.
• Move the antenna leads away from any wire runs to the receiver/control.
• Plug the receiver/control into a different outlet so that it and the radio or
television receiver are on different branch circuits.
If necessary, the user should consult the dealer or an experienced
radio/television technician for additional suggestions. The user or installer
may find the following booklet prepared by the Federal Communications
Commission helpful: "Interference Handbook"
This booklet is available under Stock No. 004-000-00450-7 from the U.S.
Government Printing Office, Washington, DC 20402.
The user shall not make any changes or modifications to the equipment
unless authorized by the Installation Instructions or User's Manual.
Unauthorized changes or modifications could void the user's authority to
operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful
interference (2) This device must accept any interference received, including
interference that may cause undesired operation.
www.honeywell.com/security
Activates Upon...
System armed/disarmed as follows:
ON = system armed Away, Stay, or Instant (NO
contact connect to COM)
OFF = system disarmed (NC contact connects to
COM)
Normally on (lighted) when power is applied.
Flickering indicates RF is being processed.
Lights when RF activity is present.
FCC STATEMENT